Application of Non-Stop-Flow Differential Pulse Voltammetry at a Tubular Detector of Silver Solid Amalgam for Electrochemical Determination of Lomustine (CCNU)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10210465" target="_blank" >RIV/00216208:11310/14:10210465 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/14:00426367
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201300456" target="_blank" >http://dx.doi.org/10.1002/elan.201300456</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201300456" target="_blank" >10.1002/elan.201300456</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Non-Stop-Flow Differential Pulse Voltammetry at a Tubular Detector of Silver Solid Amalgam for Electrochemical Determination of Lomustine (CCNU)
Popis výsledku v původním jazyce
An application of the flow differential pulse voltammetry with tubular detector based on silver solid amalgam for determination of antineoplastic drug lomustine in pharmaceutical preparations is presented. The highest sensitivity was obtained in [0.10moldm(-3) MES; 2.00moldm(-3) NaCl; pH6.0]:EtOH (9:1) with flow rate 0.50mLmin(-1), and the magnitude of the modulation amplitude -0.070V. The calibration dependence was linear in the range 1x10(-6)-1x10(-4)moldm(-3) (R-2=0.999). The limit of detection was 1.5x10(-7)moldm(-3). This method was successfully used for determination of lomustine in real samples of chemotherapy drug CeeNU Lomustine 40mg.
Název v anglickém jazyce
Application of Non-Stop-Flow Differential Pulse Voltammetry at a Tubular Detector of Silver Solid Amalgam for Electrochemical Determination of Lomustine (CCNU)
Popis výsledku anglicky
An application of the flow differential pulse voltammetry with tubular detector based on silver solid amalgam for determination of antineoplastic drug lomustine in pharmaceutical preparations is presented. The highest sensitivity was obtained in [0.10moldm(-3) MES; 2.00moldm(-3) NaCl; pH6.0]:EtOH (9:1) with flow rate 0.50mLmin(-1), and the magnitude of the modulation amplitude -0.070V. The calibration dependence was linear in the range 1x10(-6)-1x10(-4)moldm(-3) (R-2=0.999). The limit of detection was 1.5x10(-7)moldm(-3). This method was successfully used for determination of lomustine in real samples of chemotherapy drug CeeNU Lomustine 40mg.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
306-311
Kód UT WoS článku
000331982500011
EID výsledku v databázi Scopus
—