Construction and Application of Flow Enzymatic Biosensor Based of Silver Solid Amalgam Electrode for Determination of Sarcosine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F15%3A00446079" target="_blank" >RIV/61388955:_____/15:00446079 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/15:10318000
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201500246" target="_blank" >http://dx.doi.org/10.1002/elan.201500246</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201500246" target="_blank" >10.1002/elan.201500246</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Construction and Application of Flow Enzymatic Biosensor Based of Silver Solid Amalgam Electrode for Determination of Sarcosine
Popis výsledku v původním jazyce
In this paper, the flow amperometric enzymatic biosensor based on polished silver solid amalgam electrode for determination of sarcosine in model sample under flow injection analysis conditions is presented. The biosensor works on principle of electrochemical detection of oxygen decrease during enzymatic reaction which is directly proportional to the concentration of sarcosine in sample. The whole preparation process takes about 3 h. The RSD of repeatability of 10 consecutive measurements is 1.6% (csarcosine=1.0x10-4 moldm-3). Under optimal conditions the calibration dependence was linear in the range 7.5x10-6 – 5.0x10-4 moldm-3 and limit of detection was 2.0x10-6 moldm-3.
Název v anglickém jazyce
Construction and Application of Flow Enzymatic Biosensor Based of Silver Solid Amalgam Electrode for Determination of Sarcosine
Popis výsledku anglicky
In this paper, the flow amperometric enzymatic biosensor based on polished silver solid amalgam electrode for determination of sarcosine in model sample under flow injection analysis conditions is presented. The biosensor works on principle of electrochemical detection of oxygen decrease during enzymatic reaction which is directly proportional to the concentration of sarcosine in sample. The whole preparation process takes about 3 h. The RSD of repeatability of 10 consecutive measurements is 1.6% (csarcosine=1.0x10-4 moldm-3). Under optimal conditions the calibration dependence was linear in the range 7.5x10-6 – 5.0x10-4 moldm-3 and limit of detection was 2.0x10-6 moldm-3.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
2559-2566
Kód UT WoS článku
000368339700008
EID výsledku v databázi Scopus
2-s2.0-84954440405