The influence of the substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10282374" target="_blank" >RIV/00216208:11310/14:10282374 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24620/14:#0000456
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.201400604" target="_blank" >http://dx.doi.org/10.1002/jssc.201400604</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201400604" target="_blank" >10.1002/jssc.201400604</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of the substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Popis výsledku v původním jazyce
Three newly synthesized chiral selectors, namely, 2(I)-O-, 3(I)-O-, and 6(I)-O-carboxymethyl--cyclodextrin, native -cyclodextrin, and commercially available carboxymethylated -cyclodextrin with degree of substitution of 3-6 were used as additives in a background electrolyte composed of phosphate buffer at 20mmol/L concentration and pH 2.5. This system was used for the analysis of several biologically significant low-molecular-mass chiral compounds by capillary electrophoresis. The results confirmed thatthe position of carboxymethyl group influences the enantioseparation efficiency of all the studied analytes. The 2(I)-O- and 3(I)-O- regioisomers provide a significantly better resolution than native -cyclodextrin, while the 6(I)-O-regioisomer gives only a slightly better enantioseparation than native -cyclodextrin. The application of -cyclodextrin possessing higher number of carboxymethyl groups led to the best resolution for the majority of the compounds analyzed.
Název v anglickém jazyce
The influence of the substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Popis výsledku anglicky
Three newly synthesized chiral selectors, namely, 2(I)-O-, 3(I)-O-, and 6(I)-O-carboxymethyl--cyclodextrin, native -cyclodextrin, and commercially available carboxymethylated -cyclodextrin with degree of substitution of 3-6 were used as additives in a background electrolyte composed of phosphate buffer at 20mmol/L concentration and pH 2.5. This system was used for the analysis of several biologically significant low-molecular-mass chiral compounds by capillary electrophoresis. The results confirmed thatthe position of carboxymethyl group influences the enantioseparation efficiency of all the studied analytes. The 2(I)-O- and 3(I)-O- regioisomers provide a significantly better resolution than native -cyclodextrin, while the 6(I)-O-regioisomer gives only a slightly better enantioseparation than native -cyclodextrin. The application of -cyclodextrin possessing higher number of carboxymethyl groups led to the best resolution for the majority of the compounds analyzed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
19
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
2779-2784
Kód UT WoS článku
000342909300020
EID výsledku v databázi Scopus
—