The influence of substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F14%3A43897172" target="_blank" >RIV/60461373:22340/14:43897172 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.201400604" target="_blank" >http://dx.doi.org/10.1002/jssc.201400604</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201400604" target="_blank" >10.1002/jssc.201400604</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Popis výsledku v původním jazyce
Three newly synthesized chiral selectors, namely, 2I-O-, 3I-O-, and 6I-O-carboxymethyl-?-cyclodextrin, native ?-cyclodextrin, and commercially available carboxymethylated ?-cyclodextrin with degree of substitution of 3-6 were used as additives in a background electrolyte composed of phosphate buffer at 20 mmol/L concentration and pH 2.5. This systém was used for the analysis of several biologically significant low-molecular-mass chiral compounds by capillary electrophoresis. The results confirmed that the position of carboxymethyl group influences the enantioseparation efficiency of all the studied analytes. The 2I-O- and 3I-O- regioisomers provide a significantly better resolution than native ?-cyclodextrin, while the 6I-O-regioisomer gives only a slightly better enantioseparation than native ?-cyclodextrin. The application of ?-cyclodextrin possessing higher number of carboxymethyl groups led to the best resolution for the majority of the compounds analyzed.
Název v anglickém jazyce
The influence of substituent position in monocarboxymethyl-gamma-cyclodextrins on enantioselectivity in capillary electrophoresis
Popis výsledku anglicky
Three newly synthesized chiral selectors, namely, 2I-O-, 3I-O-, and 6I-O-carboxymethyl-?-cyclodextrin, native ?-cyclodextrin, and commercially available carboxymethylated ?-cyclodextrin with degree of substitution of 3-6 were used as additives in a background electrolyte composed of phosphate buffer at 20 mmol/L concentration and pH 2.5. This systém was used for the analysis of several biologically significant low-molecular-mass chiral compounds by capillary electrophoresis. The results confirmed that the position of carboxymethyl group influences the enantioseparation efficiency of all the studied analytes. The 2I-O- and 3I-O- regioisomers provide a significantly better resolution than native ?-cyclodextrin, while the 6I-O-regioisomer gives only a slightly better enantioseparation than native ?-cyclodextrin. The application of ?-cyclodextrin possessing higher number of carboxymethyl groups led to the best resolution for the majority of the compounds analyzed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F0453" target="_blank" >GAP206/12/0453: Afinitní kapilární elektromigrační metody pro selektivní nanoanalýzu biomolekul a studium jejich interakcí</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Sciences online
ISSN
1615-9314
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
19
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
2779-2784
Kód UT WoS článku
000342909300020
EID výsledku v databázi Scopus
—