Voltammetric determination of 1-hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide by voltammetry at a glassy carbon electrode in microvolumes of dimethyl sulfoxide
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10336891" target="_blank" >RIV/00216208:11310/16:10336891 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081707:_____/16:00506692
Výsledek na webu
<a href="https://web.natur.cuni.cz/analchem/isc-mac/" target="_blank" >https://web.natur.cuni.cz/analchem/isc-mac/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of 1-hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide by voltammetry at a glassy carbon electrode in microvolumes of dimethyl sulfoxide
Popis výsledku v původním jazyce
Voltammetric reduction and oxidation of 1-hydroxy-N-(4-nitrophenyl) naphthalene-2-carboxamide was investigated at glassy carbon electrode in dimethyl sulfoxide. Cyclic voltammetry was used to investigate the mechanism of reduction of nitro group and oxidation of hydroxyl group. The analyte was successfully determined in dimethyl sulfoxide by differential pulse voltammetry and the whole voltammetric procedure was miniaturised. Square wave voltammetry was employed to reduce the interference from dissolved oxygen. Determination in one drop (20 mu L) of 0.1 mol L-1 tetrabutyl-ammonium tetrafluoroborate in dimethyl sulfoxide provided very similar results compared to determination in the bulk solution. Limits of quantification were 5.0 mu mol L-1 for cathodic voltammetry and 5.3 mu mol L-1 for anodic voltammetry.
Název v anglickém jazyce
Voltammetric determination of 1-hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide by voltammetry at a glassy carbon electrode in microvolumes of dimethyl sulfoxide
Popis výsledku anglicky
Voltammetric reduction and oxidation of 1-hydroxy-N-(4-nitrophenyl) naphthalene-2-carboxamide was investigated at glassy carbon electrode in dimethyl sulfoxide. Cyclic voltammetry was used to investigate the mechanism of reduction of nitro group and oxidation of hydroxyl group. The analyte was successfully determined in dimethyl sulfoxide by differential pulse voltammetry and the whole voltammetric procedure was miniaturised. Square wave voltammetry was employed to reduce the interference from dissolved oxygen. Determination in one drop (20 mu L) of 0.1 mol L-1 tetrabutyl-ammonium tetrafluoroborate in dimethyl sulfoxide provided very similar results compared to determination in the bulk solution. Limits of quantification were 5.0 mu mol L-1 for cathodic voltammetry and 5.3 mu mol L-1 for anodic voltammetry.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS OF THE 12TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY
ISBN
978-80-7444-044-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
23-27
Název nakladatele
CHARLES UNIV, FAC SCIENCE
Místo vydání
PRAGUE 2
Místo konání akce
Prague
Datum konání akce
22. 9. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000391253800005