Spectrophotometric determination of ligand-protein ratio in B2M3-DTPA monoclonal conjugates based on yttrium-methylthymol blue complex
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10381619" target="_blank" >RIV/00216208:11310/18:10381619 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1007/s00706-018-2248-1" target="_blank" >https://doi.org/10.1007/s00706-018-2248-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-018-2248-1" target="_blank" >10.1007/s00706-018-2248-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectrophotometric determination of ligand-protein ratio in B2M3-DTPA monoclonal conjugates based on yttrium-methylthymol blue complex
Popis výsledku v původním jazyce
Monoclonal conjugates using radionuclides are widely used in the diagnosis or therapy of cancer. A number of ligand molecules per protein molecule (L/P ratio) are a crucial factor affecting the monoclonal conjugate efficacy and safety. For proper and accurate dosing of monoclonal conjugates, it is necessary to establish the L/P ratio before they are applied. The aim of this work was the development of a simple, efficient, non-radioactive, and low-cost spectrophotometric method for L/P ratio measurement. The method is based on transchelation reaction between the monoclonal conjugate and yttrium(III)-methylthymol blue complex followed at wavelength of 590 nm. The method operates in the L/P ratio range of 0.32-8.00 and the results are satisfactorily comparable to the conventional mass spectrometric method.
Název v anglickém jazyce
Spectrophotometric determination of ligand-protein ratio in B2M3-DTPA monoclonal conjugates based on yttrium-methylthymol blue complex
Popis výsledku anglicky
Monoclonal conjugates using radionuclides are widely used in the diagnosis or therapy of cancer. A number of ligand molecules per protein molecule (L/P ratio) are a crucial factor affecting the monoclonal conjugate efficacy and safety. For proper and accurate dosing of monoclonal conjugates, it is necessary to establish the L/P ratio before they are applied. The aim of this work was the development of a simple, efficient, non-radioactive, and low-cost spectrophotometric method for L/P ratio measurement. The method is based on transchelation reaction between the monoclonal conjugate and yttrium(III)-methylthymol blue complex followed at wavelength of 590 nm. The method operates in the L/P ratio range of 0.32-8.00 and the results are satisfactorily comparable to the conventional mass spectrometric method.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
—
Svazek periodika
149
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
5
Strana od-do
1653-1657
Kód UT WoS článku
000442501400022
EID výsledku v databázi Scopus
2-s2.0-85051640199