Interlaboratory study of ethanol usage as an internal standard in direct determination of volatile compounds in alcoholic products
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F19%3A10409578" target="_blank" >RIV/00216208:11310/19:10409578 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1051/bioconf/20191502030" target="_blank" >https://doi.org/10.1051/bioconf/20191502030</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/bioconf/20191502030" target="_blank" >10.1051/bioconf/20191502030</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interlaboratory study of ethanol usage as an internal standard in direct determination of volatile compounds in alcoholic products
Popis výsledku v původním jazyce
A collaborative interlaboratory study on the method of direct quantitation of volatile compounds in spirit drinks and alcoholic products was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic product, as an internal standard. In this study 9 laboratories from 4 different countries were supplied with standard solutions for gas chromatographic measurements. Five aqueous ethanol 40% (v/v) standard solutions containing target compounds in concentrations ranging from 10 mg/L to 400 mg/L of absolute alcohol were prepared and sent to the participants for quantification of acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, 2-methyl-1-propanol, 1-butanol and 3-methyl-1-butanol. The interlaboratory study was evaluated according to the ISO 5725 standards and the Eurachem guide. The within-laboratory precision varied between 0.4% and 7.5% for all samples and compounds, showing a sufficiently high repeatability of the method. The between-laboratory precision was found to vary within a satisfactory range of 0.5% o 10.0%. Precision of the method was well within the range predicted by the Horwitz equation for all analytes. The analysis of trueness showed that the bias of the method is insignificant at the significance level alpha = 5%. The determined concentrations of the analytes compared well to the gravimetrical values thus showing very satisfactory accuracy of the method. The results of the interlaboratory study confirmed that "Ethanol as Internal Standard" method is robust and reliable and can be used as a standard reference method for analysing volatile compounds in water-ethanol samples. The possibilities of method validation according to the previously obtained experimental data were shown.
Název v anglickém jazyce
Interlaboratory study of ethanol usage as an internal standard in direct determination of volatile compounds in alcoholic products
Popis výsledku anglicky
A collaborative interlaboratory study on the method of direct quantitation of volatile compounds in spirit drinks and alcoholic products was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic product, as an internal standard. In this study 9 laboratories from 4 different countries were supplied with standard solutions for gas chromatographic measurements. Five aqueous ethanol 40% (v/v) standard solutions containing target compounds in concentrations ranging from 10 mg/L to 400 mg/L of absolute alcohol were prepared and sent to the participants for quantification of acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, 2-methyl-1-propanol, 1-butanol and 3-methyl-1-butanol. The interlaboratory study was evaluated according to the ISO 5725 standards and the Eurachem guide. The within-laboratory precision varied between 0.4% and 7.5% for all samples and compounds, showing a sufficiently high repeatability of the method. The between-laboratory precision was found to vary within a satisfactory range of 0.5% o 10.0%. Precision of the method was well within the range predicted by the Horwitz equation for all analytes. The analysis of trueness showed that the bias of the method is insignificant at the significance level alpha = 5%. The determined concentrations of the analytes compared well to the gravimetrical values thus showing very satisfactory accuracy of the method. The results of the interlaboratory study confirmed that "Ethanol as Internal Standard" method is robust and reliable and can be used as a standard reference method for analysing volatile compounds in water-ethanol samples. The possibilities of method validation according to the previously obtained experimental data were shown.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
42nd World Congress of Vine and Wine
ISBN
978-2-85038-010-5
ISSN
2117-4458
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
E D P Sciences
Místo vydání
CEDEX A
Místo konání akce
Geneva
Datum konání akce
15. 7. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000509352700066