Comparison of hazes in freshly bottled and aged beer by multiple angle turbidimetry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F10%3A10082463" target="_blank" >RIV/00216208:11320/10:10082463 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of hazes in freshly bottled and aged beer by multiple angle turbidimetry
Popis výsledku v původním jazyce
The hazes of freshly bottled and aged pale lager beers determined with the 12° and 90° dual angle laboratory hazemeters and 10° to 90° range photogoniometer were compared and evaluated. The instruments were standardised in EBC formazin units. In freshlybottled beer, the forward (12°-25°) haze values were smaller approximately by a factor of three than the nephelometric (90°) values which yielded 0.33 EBC units. In aged beer, the forward haze was greater than the nephelometric one. Whereas the aged beershowed the greatest and the fresh beer the lowest intensity of scattered light, the formazin suspension intensity was in between. Due to the standardisation of the beer scattered intensities by relation to that of formazin, the standardised nephelometric haze in non-aged beer was greater than the forward haze, and vice versa in aged beer.
Název v anglickém jazyce
Comparison of hazes in freshly bottled and aged beer by multiple angle turbidimetry
Popis výsledku anglicky
The hazes of freshly bottled and aged pale lager beers determined with the 12° and 90° dual angle laboratory hazemeters and 10° to 90° range photogoniometer were compared and evaluated. The instruments were standardised in EBC formazin units. In freshlybottled beer, the forward (12°-25°) haze values were smaller approximately by a factor of three than the nephelometric (90°) values which yielded 0.33 EBC units. In aged beer, the forward haze was greater than the nephelometric one. Whereas the aged beershowed the greatest and the fresh beer the lowest intensity of scattered light, the formazin suspension intensity was in between. Due to the standardisation of the beer scattered intensities by relation to that of formazin, the standardised nephelometric haze in non-aged beer was greater than the forward haze, and vice versa in aged beer.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Czech Journal of Food Sciences
ISSN
1212-1800
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000275290500005
EID výsledku v databázi Scopus
—