Electron density measurements in low-pressure plasmas using cutoff probes and comparison with hairpin and Langmuir probes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F24%3A10484604" target="_blank" >RIV/00216208:11320/24:10484604 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Oz_OmSpjWe" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Oz_OmSpjWe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0192799" target="_blank" >10.1063/5.0192799</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electron density measurements in low-pressure plasmas using cutoff probes and comparison with hairpin and Langmuir probes
Popis výsledku v původním jazyce
We present a comparative study of electron density obtained in a low-temperature plasma by the cutoff probe and compare the results with data from both the hairpin and the Langmuir probes. The measurements with different probes were conducted in a DC discharge generated by an iron hollow cathode under identical experimental conditions. This comparative analysis provides insight into the reliability and consistency of electron density measurements across different probe types in this specific experimental setup. The information acquired from the cutoff and hairpin probes enables electron density measurements within the frequency range limitations of the instruments. Measurements of electron density are performed in a mixture of argon and oxygen at a low pressure of 5 Pa, in dependence on the discharge current and Ar:O-2 mixture ratio. A qualitative discussion of the obtained results is provided.
Název v anglickém jazyce
Electron density measurements in low-pressure plasmas using cutoff probes and comparison with hairpin and Langmuir probes
Popis výsledku anglicky
We present a comparative study of electron density obtained in a low-temperature plasma by the cutoff probe and compare the results with data from both the hairpin and the Langmuir probes. The measurements with different probes were conducted in a DC discharge generated by an iron hollow cathode under identical experimental conditions. This comparative analysis provides insight into the reliability and consistency of electron density measurements across different probe types in this specific experimental setup. The information acquired from the cutoff and hairpin probes enables electron density measurements within the frequency range limitations of the instruments. Measurements of electron density are performed in a mixture of argon and oxygen at a low pressure of 5 Pa, in dependence on the discharge current and Ar:O-2 mixture ratio. A qualitative discussion of the obtained results is provided.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
<a href="/cs/project/EH22_008%2F0004572" target="_blank" >EH22_008/0004572: Kvantové materiály pro aplikace v udržitelných technologiích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physics of Plasmas
ISSN
1070-664X
e-ISSN
1089-7674
Svazek periodika
31
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
043510
Kód UT WoS článku
001205630400001
EID výsledku v databázi Scopus
2-s2.0-85190954117