Reproducibility of thermal threshold assessment in small-fibre neuropathy patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F05%3A00031732" target="_blank" >RIV/00216224:14110/05:00031732 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reproducibility of thermal threshold assessment in small-fibre neuropathy patients
Popis výsledku v původním jazyce
To evaluate the test-retest reproducibility of thermal threshold testing (TTT) in small-fibre neuropathy (SFN) patients. Methods: Thermal thresholds for cold (CP) and warm (WP) perception were repeatedly evaluated over a period of 1 week in a group of 58SFN patients and in 30 healthy volunteers. Thermal thresholds were established in the hand and foot using 3 different algorithms. The coefficients of repeatability (CR) (expressed as 2 multiple of SDdif calculated as, where n represents the number of all measurements) varied between 0.72 and 1.5 degrees of Centigrade in the hand and between 2.2 and 3.7 degrees of Centigrade in the foot in healthy volunteers and SFN patients respectively. The reproducibility of all the tests in the hand and of CP testsin the foot was higher in healthy volunteers in comparison with SFN patients. Thermal threshold values in both SFN patients and healthy volunteers showed higher reproducibility in the hand compared with those in the foot.
Název v anglickém jazyce
Reproducibility of thermal threshold assessment in small-fibre neuropathy patients
Popis výsledku anglicky
To evaluate the test-retest reproducibility of thermal threshold testing (TTT) in small-fibre neuropathy (SFN) patients. Methods: Thermal thresholds for cold (CP) and warm (WP) perception were repeatedly evaluated over a period of 1 week in a group of 58SFN patients and in 30 healthy volunteers. Thermal thresholds were established in the hand and foot using 3 different algorithms. The coefficients of repeatability (CR) (expressed as 2 multiple of SDdif calculated as, where n represents the number of all measurements) varied between 0.72 and 1.5 degrees of Centigrade in the hand and between 2.2 and 3.7 degrees of Centigrade in the foot in healthy volunteers and SFN patients respectively. The reproducibility of all the tests in the hand and of CP testsin the foot was higher in healthy volunteers in comparison with SFN patients. Thermal threshold values in both SFN patients and healthy volunteers showed higher reproducibility in the hand compared with those in the foot.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scripta medica
ISSN
1211-3395
e-ISSN
—
Svazek periodika
78
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—