Correction of Physiological Artifacts in Multi-Echo fMRI Data-Evaluation of Possible RETROICOR Implementations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F25%3A00141512" target="_blank" >RIV/00216224:14110/25:00141512 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/hbm.70264" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/hbm.70264</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/hbm.70264" target="_blank" >10.1002/hbm.70264</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correction of Physiological Artifacts in Multi-Echo fMRI Data-Evaluation of Possible RETROICOR Implementations
Popis výsledku v původním jazyce
The study evaluates the efficacy of RETROICOR (Retrospective Image Correction) in mitigating physiological artifacts within multi-echo (ME) fMRI data. Two RETROICOR implementations were compared: applying corrections to individual echoes (RTC_ind) versus composite multi-echo data (RTC_comp). Data from 50 healthy participants were collected using diverse acquisition parameters, including multiband acceleration factors and varying flip angles, on a Siemens Prisma 3T scanner. Key metrics such as temporal signal-to-noise ratio (tSNR), signal fluctuation sensitivity (SFS), and variance of residuals demonstrated improved data quality in both RETROICOR models, particularly in moderately accelerated runs (multiband factors 4 and 6) with lower flip angles (45 degrees). Differences between RTC_ind and RTC_comp were minimal, suggesting both methods are viable for practical applications. While the highest acceleration (multiband factor 8) degraded data quality, RETROICOR's compatibility with faster acquisition sequences was confirmed. These findings underscore the importance of optimizing acquisition parameters and noise correction techniques for reliable fMRI investigations.
Název v anglickém jazyce
Correction of Physiological Artifacts in Multi-Echo fMRI Data-Evaluation of Possible RETROICOR Implementations
Popis výsledku anglicky
The study evaluates the efficacy of RETROICOR (Retrospective Image Correction) in mitigating physiological artifacts within multi-echo (ME) fMRI data. Two RETROICOR implementations were compared: applying corrections to individual echoes (RTC_ind) versus composite multi-echo data (RTC_comp). Data from 50 healthy participants were collected using diverse acquisition parameters, including multiband acceleration factors and varying flip angles, on a Siemens Prisma 3T scanner. Key metrics such as temporal signal-to-noise ratio (tSNR), signal fluctuation sensitivity (SFS), and variance of residuals demonstrated improved data quality in both RETROICOR models, particularly in moderately accelerated runs (multiband factors 4 and 6) with lower flip angles (45 degrees). Differences between RTC_ind and RTC_comp were minimal, suggesting both methods are viable for practical applications. While the highest acceleration (multiband factor 8) degraded data quality, RETROICOR's compatibility with faster acquisition sequences was confirmed. These findings underscore the importance of optimizing acquisition parameters and noise correction techniques for reliable fMRI investigations.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
<a href="/cs/project/GA23-06957S" target="_blank" >GA23-06957S: Nové strategie ve zpracování multi-echo fMRI dat</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Human Brain mapping
ISSN
1065-9471
e-ISSN
1097-0193
Svazek periodika
46
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
20
Strana od-do
1-20
Kód UT WoS článku
001512998500001
EID výsledku v databázi Scopus
2-s2.0-105008999745