Determination of pyrroloquinoline quinone by capillary zone electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F00%3A00003262" target="_blank" >RIV/00216224:14310/00:00003262 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of pyrroloquinoline quinone by capillary zone electrophoresis
Popis výsledku v původním jazyce
A new method for the determination of pyrroloquinoline quinone by capillary zone electrophoresis has been developed. Separation conditions have been optimised with the respect to different parameters including pH and ionic strength of the background electrolyte, separation voltage and temperature of the capillary. A buffer consisting of 50 mM b-alanine - HCl pH 3.0 was found to be the most suitable electrolyte for this separation. An applied voltage of 25 kV (negative polarity) and a temperature of 25 oC gave the best analysis of pyrroloquinoline quinone. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mM (correlation coefficient 0.9998) with a detection limit of 0.1- 0.2 mM. The inter-day reproducibility ofthe peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.18 %.
Název v anglickém jazyce
Determination of pyrroloquinoline quinone by capillary zone electrophoresis
Popis výsledku anglicky
A new method for the determination of pyrroloquinoline quinone by capillary zone electrophoresis has been developed. Separation conditions have been optimised with the respect to different parameters including pH and ionic strength of the background electrolyte, separation voltage and temperature of the capillary. A buffer consisting of 50 mM b-alanine - HCl pH 3.0 was found to be the most suitable electrolyte for this separation. An applied voltage of 25 kV (negative polarity) and a temperature of 25 oC gave the best analysis of pyrroloquinoline quinone. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mM (correlation coefficient 0.9998) with a detection limit of 0.1- 0.2 mM. The inter-day reproducibility ofthe peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.18 %.
Klasifikace
Druh
B - Odborná kniha
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F97%2F0340" target="_blank" >GA525/97/0340: Aktivita bakterie Thiobacilus ferrooxidans ve vztahu k ekotoxikologii sulfidických odpadů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
ISSN 0378-4347
Počet stran knihy
7
Název nakladatele
Elsevier
Místo vydání
Amsterdam
Kód UT WoS knihy
—