Elimination Voltammetry of Adenine and Cytosine Mixtures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F01%3A00005416" target="_blank" >RIV/00216224:14310/01:00005416 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Elimination Voltammetry of Adenine and Cytosine Mixtures
Popis výsledku v původním jazyce
The elimination voltammetry with linear scan (EVLS) was used to study adenine and cytosine reduction signals at the mercury electrode. In comparison with the linear scan voltammetry providing only one unresolved peak, two elimination functions provide good resolution of individual peaks and significant increase of sensitivity.Two selected functions give two well resolved peaks of adenine and cytosine in a wide concentration range, while the linear sweep voltammetry gives badly resolved peaks due to thehydrogen evolution. The best resolution of peaks is observed in acetate buffer at pH 3.8 and a detection limit for both substances is 500 nM. The concentration dependence of EVLS peak heights for one substance at the constant concentration of the other substance is linear. The peak potentials differ in these elimination functions. The difference in EVLS peak potentials gives the possibility to evaluate .EVLS contributes to the resolution of cathodic signals of purine and pyrimidine bases
Název v anglickém jazyce
Elimination Voltammetry of Adenine and Cytosine Mixtures
Popis výsledku anglicky
The elimination voltammetry with linear scan (EVLS) was used to study adenine and cytosine reduction signals at the mercury electrode. In comparison with the linear scan voltammetry providing only one unresolved peak, two elimination functions provide good resolution of individual peaks and significant increase of sensitivity.Two selected functions give two well resolved peaks of adenine and cytosine in a wide concentration range, while the linear sweep voltammetry gives badly resolved peaks due to thehydrogen evolution. The best resolution of peaks is observed in acetate buffer at pH 3.8 and a detection limit for both substances is 500 nM. The concentration dependence of EVLS peak heights for one substance at the constant concentration of the other substance is linear. The peak potentials differ in these elimination functions. The difference in EVLS peak potentials gives the possibility to evaluate .EVLS contributes to the resolution of cathodic signals of purine and pyrimidine bases
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV204%2F97%2FK084" target="_blank" >GV204/97/K084: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bioelectrochemistry
ISSN
1567-5394
e-ISSN
—
Svazek periodika
2001
Číslo periodika v rámci svazku
54
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
131
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—