Use of artificial neural networks for the evaluation UV-Vis spectra of adenine and cytosine in mixtures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F02%3A00006278" target="_blank" >RIV/00216224:14310/02:00006278 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of artificial neural networks for the evaluation UV-Vis spectra of adenine and cytosine in mixtures
Popis výsledku v původním jazyce
Recently we have demonstrated advantages of artificial neural networks (ANNs) for quantification of nucleic acid bases mixtures from overlapping voltammetric signals. In this work ANNs were applied to analyze adenine-cytosine mixtures from UV-Vis spectra. Spectra of these compounds are highly similar (lambda max 261 and 270nm, respectively) and common spectral approaches of analysis are failing. The optimal ANN architecture, able to model the system, was established. Software of ANNs method was from TRAJAN 6 program. Using the suitable experimental design with soft ANN modeling adenine - cytosine mixtures can be quantified with an excellent precision (less than 1%). Generally, ANNs open many possibilities for the analysis of mixtures of biologically important substances with very overlapped signals, even without the explicit knowledge of their behavior.
Název v anglickém jazyce
Use of artificial neural networks for the evaluation UV-Vis spectra of adenine and cytosine in mixtures
Popis výsledku anglicky
Recently we have demonstrated advantages of artificial neural networks (ANNs) for quantification of nucleic acid bases mixtures from overlapping voltammetric signals. In this work ANNs were applied to analyze adenine-cytosine mixtures from UV-Vis spectra. Spectra of these compounds are highly similar (lambda max 261 and 270nm, respectively) and common spectral approaches of analysis are failing. The optimal ANN architecture, able to model the system, was established. Software of ANNs method was from TRAJAN 6 program. Using the suitable experimental design with soft ANN modeling adenine - cytosine mixtures can be quantified with an excellent precision (less than 1%). Generally, ANNs open many possibilities for the analysis of mixtures of biologically important substances with very overlapped signals, even without the explicit knowledge of their behavior.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA1163201" target="_blank" >IAA1163201: Využití adsorptivní přenosové a eliminační techniky pro elektrochemickou analýzu oligonukleotidů a nukleových kyselin</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Chemické listy
ISBN
0009-2770
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
482
Název nakladatele
Česká společnost chemická
Místo vydání
Praha
Místo konání akce
30.6. - 4.7. 2002, Brno, Česká republika
Datum konání akce
1. 1. 2002
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—