Eliminační voltametrie oligonukleotidů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F04%3A00011234" target="_blank" >RIV/00216224:14310/04:00011234 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Elimination voltammetry of oligonucleotides
Popis výsledku v původním jazyce
Oligodeoxynucleotides (ODNs) containing adenines (A), cytosines (C) and guanines (G) are electroactive species and produce cathodic (A,C) and anodic (G) voltammetric peaks at mercury electrodes. The reduction peak potentials of A and C are located very close to each other, so that usually only one voltammetric peak is observed. One signal only can be observed even when adsorptive transfer stripping voltammetry (AdTSV) is used. The elimination voltammetry with linear scan (EVLS) used in connection with ahanging mercury electrode is able to distinguish between A and C signals. The EVLS is based on elimination of one or two selected currents from total currents measured by linear scan voltammetry. The function eliminating kinetic and charging currents, and conserving the diffusion current was calculated for the case of adsorbed electroactive substance, and the theoretical elimination curve has a peak-counterpeak form. Various elimination functions were applied in the analysis of oligonuc
Název v anglickém jazyce
Elimination voltammetry of oligonucleotides
Popis výsledku anglicky
Oligodeoxynucleotides (ODNs) containing adenines (A), cytosines (C) and guanines (G) are electroactive species and produce cathodic (A,C) and anodic (G) voltammetric peaks at mercury electrodes. The reduction peak potentials of A and C are located very close to each other, so that usually only one voltammetric peak is observed. One signal only can be observed even when adsorptive transfer stripping voltammetry (AdTSV) is used. The elimination voltammetry with linear scan (EVLS) used in connection with ahanging mercury electrode is able to distinguish between A and C signals. The EVLS is based on elimination of one or two selected currents from total currents measured by linear scan voltammetry. The function eliminating kinetic and charging currents, and conserving the diffusion current was calculated for the case of adsorbed electroactive substance, and the theoretical elimination curve has a peak-counterpeak form. Various elimination functions were applied in the analysis of oligonuc
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts I - 55th Annual Meeting of the ISE
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
429-429
Název nakladatele
International Society of Electrochemistry
Místo vydání
Thessaloniki, Creece
Místo konání akce
Thessaloniki, Greece
Datum konání akce
19. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—