Elimination voltammetry of short oligonucleotides
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F02%3A00006480" target="_blank" >RIV/00216224:14330/02:00006480 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Elimination voltammetry of short oligonucleotides
Popis výsledku v původním jazyce
Oligonucleotides containing adenines (A) or cytosines (C) yield reduction voltammetric peaks on mercury electrodes. The peak potentials of both bases are located very close to each other on the potential scale, so that usually only one voltammetric peakis observed. One signal only can be observed even when adsorptive transfer stripping voltammetry (AdTSV) is used. In the present work we have used elimination voltammetry with linear scan (EVLS) in connection with hanging mercury electrode, and shown that this electrochemical method is able to distinguish the two signals. EVLS is based on elimination of one or two selected currents from total currents measured by linear scan voltammetry. The function eliminating kinetic and charging currents, and conserving the diffusion current was calculated for the case of adsorbed electroactive substance. The theoretical elimination curve has a peak-counterpeak form. This elimination function was applied to the analysis of short oligonucleotides con
Název v anglickém jazyce
Elimination voltammetry of short oligonucleotides
Popis výsledku anglicky
Oligonucleotides containing adenines (A) or cytosines (C) yield reduction voltammetric peaks on mercury electrodes. The peak potentials of both bases are located very close to each other on the potential scale, so that usually only one voltammetric peakis observed. One signal only can be observed even when adsorptive transfer stripping voltammetry (AdTSV) is used. In the present work we have used elimination voltammetry with linear scan (EVLS) in connection with hanging mercury electrode, and shown that this electrochemical method is able to distinguish the two signals. EVLS is based on elimination of one or two selected currents from total currents measured by linear scan voltammetry. The function eliminating kinetic and charging currents, and conserving the diffusion current was calculated for the case of adsorbed electroactive substance. The theoretical elimination curve has a peak-counterpeak form. This elimination function was applied to the analysis of short oligonucleotides con
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electrochemistry in Molecular and Microscopic Dimensions, 53rd Annual Meeting of the International Society of Electrochemistry, Book of Abstracts
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
105
Název nakladatele
Dechema e.V., Society for Chemical Engineering and Biotechnology,Frankfurt am Mai,Germany
Místo vydání
Frankfurt am Mai, Germany
Místo konání akce
September 15-20, 2002, Düsseldorf, Germany
Datum konání akce
1. 1. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—