Rozdělovací funkce energií iontů ve vodíkovém kapacitně vázaném nízkotlakém výboji
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00012694" target="_blank" >RIV/00216224:14310/05:00012694 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Energy distribution of hydrogen ions in capacitively coupled low pressure discharge
Popis výsledku v původním jazyce
The H3+, H2+ and H+ ion energy distributions (IEDs) were recorded in the 13.56 MHz hydrogen glow discharges with the energy dispersive quadrupole mass spectrometer (PPM 421) horizontally mounted between the discharge electrodes. The discharge was capacitively coupled with an asymmetric arrangement. The measurements were spatially resolved along the discharge axis, i.e. perpendicular to the electrodes, and reflected the ion flux to the grounded PPM extraction orifice 15 mm aside the electrodes. The IEDsof H3+ and H+ revealed a saddle structure that was suppressed by an effect of collisions in case of H2+. The H+ with energies up to 10 eV higher than the maximum energy of the saddle structure were observed and explained by a dissociative ionization of H2. We proved an appreciable impedance of the plasma glow region from the width changes of the saddle structure. The effect of pressure and rf power on the IEDs was studied for a fixed position at the glow region.
Název v anglickém jazyce
Energy distribution of hydrogen ions in capacitively coupled low pressure discharge
Popis výsledku anglicky
The H3+, H2+ and H+ ion energy distributions (IEDs) were recorded in the 13.56 MHz hydrogen glow discharges with the energy dispersive quadrupole mass spectrometer (PPM 421) horizontally mounted between the discharge electrodes. The discharge was capacitively coupled with an asymmetric arrangement. The measurements were spatially resolved along the discharge axis, i.e. perpendicular to the electrodes, and reflected the ion flux to the grounded PPM extraction orifice 15 mm aside the electrodes. The IEDsof H3+ and H+ revealed a saddle structure that was suppressed by an effect of collisions in case of H2+. The H+ with energies up to 10 eV higher than the maximum energy of the saddle structure were observed and explained by a dissociative ionization of H2. We proved an appreciable impedance of the plasma glow region from the width changes of the saddle structure. The effect of pressure and rf power on the IEDs was studied for a fixed position at the glow region.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD202%2F03%2FH162" target="_blank" >GD202/03/H162: Pokročilé směry ve fyzice a chemii plazmatu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta physica slovaca
ISSN
0323-0465
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
6
Strana od-do
441-446
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—