Stanovení kyanidu v ul vzorcích pomocí CE a on-line reakce s rhodanasou.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F06%3A00015670" target="_blank" >RIV/00216224:14310/06:00015670 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of cyanide in microliter samples by CE using on-capillary enzymatic reaction with rhodanese
Popis výsledku v původním jazyce
Thirteen years ago a new application for the evaluation of enzymatic reactions in capillary electrophoresis was proposed and developed, electrophoretically mediated microanalysis (EMMA). In this method the capillary is used not only as a separation medium but also as a reaction chamber. Since its discovery by Bao and Regnier [1], the EMMA methodology has been utilized in a number of biochemical systems [2,3]. In this work, the EMMA method was applied to determine cyanide after its on-capillary enzymaticreaction with rhodanese (thiosulfate: cyanide sulfur transferase, EC 2.8.1.1).Consequnetly cyanide thus could be determine as thiocyanate with adequate sensitivity by means of CE with simple UV detection. Compared to other assays, the EMMA method is rapid, can be automated, and requires only small amount of samples.
Název v anglickém jazyce
Determination of cyanide in microliter samples by CE using on-capillary enzymatic reaction with rhodanese
Popis výsledku anglicky
Thirteen years ago a new application for the evaluation of enzymatic reactions in capillary electrophoresis was proposed and developed, electrophoretically mediated microanalysis (EMMA). In this method the capillary is used not only as a separation medium but also as a reaction chamber. Since its discovery by Bao and Regnier [1], the EMMA methodology has been utilized in a number of biochemical systems [2,3]. In this work, the EMMA method was applied to determine cyanide after its on-capillary enzymaticreaction with rhodanese (thiosulfate: cyanide sulfur transferase, EC 2.8.1.1).Consequnetly cyanide thus could be determine as thiocyanate with adequate sensitivity by means of CE with simple UV detection. Compared to other assays, the EMMA method is rapid, can be automated, and requires only small amount of samples.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1120
Číslo periodika v rámci svazku
1-2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
268-272
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—