Piezoelektrický imunosensor pro polychlorované bifenyly fungující ve vodném prostředí i v organických rozpouštědlech
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F06%3A00016802" target="_blank" >RIV/00216224:14310/06:00016802 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00000493:G41__/05:25151
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases
Popis výsledku v původním jazyce
The piezoelectric quartz crystal operating in the active mode was used as a transducer for construction of immunosensors for determination polychlorinated biphenyls(PCB). An apparatus for flow-through measurements with piezosensors in pure organic phasewas constructed. The anti-PCB polyclonal antibody was immobilized in an oriented way via protein A on a smooth gold surface. The antibody high cross-reactivity for 2,4,4'-trichlorobiphenyl, 4,4'-dichlorobiphenyl and 3,3,4,4'-tetrachlorbiphenyl allowed for a specific determination of these congeners in samples. PCBs were determined either directly or using competition with a tracer, synthesized from polystyrene particles by covalent attachment of 4,4'-dichlorobiphenyl (DCB). The direct piezoelectric immunosensor operated in phosphate buffer with 5% dimethylsulphoxide. It was possible to detect coplanar PCBs in the range 1-50ppm. A higher detection limit is compensated here by the low cost and short time of analysis, below 20 min. The sam
Název v anglickém jazyce
Piezoelectric immunosensors for polychlorinated biphenyls operating in aqueous and organic phases
Popis výsledku anglicky
The piezoelectric quartz crystal operating in the active mode was used as a transducer for construction of immunosensors for determination polychlorinated biphenyls(PCB). An apparatus for flow-through measurements with piezosensors in pure organic phasewas constructed. The anti-PCB polyclonal antibody was immobilized in an oriented way via protein A on a smooth gold surface. The antibody high cross-reactivity for 2,4,4'-trichlorobiphenyl, 4,4'-dichlorobiphenyl and 3,3,4,4'-tetrachlorbiphenyl allowed for a specific determination of these congeners in samples. PCBs were determined either directly or using competition with a tracer, synthesized from polystyrene particles by covalent attachment of 4,4'-dichlorobiphenyl (DCB). The direct piezoelectric immunosensor operated in phosphate buffer with 5% dimethylsulphoxide. It was possible to detect coplanar PCBs in the range 1-50ppm. A higher detection limit is compensated here by the low cost and short time of analysis, below 20 min. The sam
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OBVTUO2003001" target="_blank" >OBVTUO2003001: PROTILÁTKY 2 - Imunosenzory bojových chemických látek a bojových biologických prostředků</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
113
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
900-910
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—