A simple LIBS method for fast quantitative analysis of fly ashes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F10%3A00047906" target="_blank" >RIV/00216224:14310/10:00047906 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A simple LIBS method for fast quantitative analysis of fly ashes
Popis výsledku v původním jazyce
An evaluation of quantitative analysis of major elements (Ca, Al, Mg, Si and Fe) present in fly ashes was made using a simple and cost effective LIBS system. LIBS parameters were optimized to obtain best sensitivity and repeatability. In this purpose different binders were compared, leading to best sensitivity and mechanical stability when a binder containing silver and cellulose was employed in a 1: 1 mass ratio. In order to be able to determine major elements in different fly ashes, a multi-matrix calibration was employed. Four reference materials were employed for calibration and five other fly ashes were selected as sample. Concentrations obtained by LIBS were compared to wet acid digestion and alkali fusion followed by ICP-OES analysis. Ca, Mg, Fe, Si and Al concentrations found using the LIBS method developed were in a good agreement with the values obtained by classical methods.
Název v anglickém jazyce
A simple LIBS method for fast quantitative analysis of fly ashes
Popis výsledku anglicky
An evaluation of quantitative analysis of major elements (Ca, Al, Mg, Si and Fe) present in fly ashes was made using a simple and cost effective LIBS system. LIBS parameters were optimized to obtain best sensitivity and repeatability. In this purpose different binders were compared, leading to best sensitivity and mechanical stability when a binder containing silver and cellulose was employed in a 1: 1 mass ratio. In order to be able to determine major elements in different fly ashes, a multi-matrix calibration was employed. Four reference materials were employed for calibration and five other fly ashes were selected as sample. Concentrations obtained by LIBS were compared to wet acid digestion and alkali fusion followed by ICP-OES analysis. Ca, Mg, Fe, Si and Al concentrations found using the LIBS method developed were in a good agreement with the values obtained by classical methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fuel
ISSN
0016-2361
e-ISSN
—
Svazek periodika
89/2010
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000280604000038
EID výsledku v databázi Scopus
—