LIBS Analysis of Crop Plants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F09%3A%230001126" target="_blank" >RIV/46747885:24210/09:#0001126 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24410/09:#0000567 RIV/00216275:25310/09:00008602
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LIBS Analysis of Crop Plants
Popis výsledku v původním jazyce
A fast and cheap method for the analysis of macronutrients (K, P, Mg and Ca) in leaves of crop plants (wheat, poppy, barley and rape) using double pulse laser induced breakdown spectrometry (LIBS) is suggested. A commercially available LIBS spectrometerwas calibrated with the aid of authentic plant samples previously analysed by AAS and ICP-OES after microwave digestion. The concentration ranges of K, P, Mg and Ca in the calibration standards were 30?66; 2.8?6.6; 1.0?5.6 and 6?24 g/ kg, respectively. Cryogenic grinding and powder pressing to pellets were used as sample preparation steps. Obtained LIBS/ICP-OES recovery values for authentic crop plant samples were 93?109% (K); 93?114% (P); 89?109% (Mg) and 94?110% (Ca). Six certified reference materials(CRMs) of plant tissues were used for the LIBS method validation. Recovery values of 96?101% were obtained for K and P, when the certified concentration of the element in the CRM was inside the concentration range of the used calibration
Název v anglickém jazyce
LIBS Analysis of Crop Plants
Popis výsledku anglicky
A fast and cheap method for the analysis of macronutrients (K, P, Mg and Ca) in leaves of crop plants (wheat, poppy, barley and rape) using double pulse laser induced breakdown spectrometry (LIBS) is suggested. A commercially available LIBS spectrometerwas calibrated with the aid of authentic plant samples previously analysed by AAS and ICP-OES after microwave digestion. The concentration ranges of K, P, Mg and Ca in the calibration standards were 30?66; 2.8?6.6; 1.0?5.6 and 6?24 g/ kg, respectively. Cryogenic grinding and powder pressing to pellets were used as sample preparation steps. Obtained LIBS/ICP-OES recovery values for authentic crop plant samples were 93?109% (K); 93?114% (P); 89?109% (Mg) and 94?110% (Ca). Six certified reference materials(CRMs) of plant tissues were used for the LIBS method validation. Recovery values of 96?101% were obtained for K and P, when the certified concentration of the element in the CRM was inside the concentration range of the used calibration
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN101630651" target="_blank" >KAN101630651: Tvorba nano-vrstev a nano-povlaků na textiliích s využitím plazmových povrchových úprav za atmosférického tlaku</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of analytical atomic spectrometry
ISSN
0267-9477
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000267273200013
EID výsledku v databázi Scopus
—