Study of the most common additives affecting electro-osmotic flow for use in capillary electrophoresis with contactless conductivity detection setup
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F13%3A00066575" target="_blank" >RIV/00216224:14310/13:00066575 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of the most common additives affecting electro-osmotic flow for use in capillary electrophoresis with contactless conductivity detection setup
Popis výsledku v původním jazyce
Electrophoretic and electroosmotic phenomena occur in capillary electrophoresis. Both phenomena manifest in dependence on in-capillary conditions. A lot of additives affecting electro-osmotic flow dynamically have been introduced over the years. Howeverno comprehensive study has been published about effects of these additives on the signal of the contactless conductivity detection (C4D) yet. C4D is nonspecific detection technique suitable for a direct analysis of ionic species, but it is sensitive to acomposition of background electrolyte as well. The subject of this contribution was present the most common additives used for electro-osmotic flow alteration, discus their suitability considering both magnitude of electro-osmotic flow affection and theeffect on the signal of the C4D.
Název v anglickém jazyce
Study of the most common additives affecting electro-osmotic flow for use in capillary electrophoresis with contactless conductivity detection setup
Popis výsledku anglicky
Electrophoretic and electroosmotic phenomena occur in capillary electrophoresis. Both phenomena manifest in dependence on in-capillary conditions. A lot of additives affecting electro-osmotic flow dynamically have been introduced over the years. Howeverno comprehensive study has been published about effects of these additives on the signal of the contactless conductivity detection (C4D) yet. C4D is nonspecific detection technique suitable for a direct analysis of ionic species, but it is sensitive to acomposition of background electrolyte as well. The subject of this contribution was present the most common additives used for electro-osmotic flow alteration, discus their suitability considering both magnitude of electro-osmotic flow affection and theeffect on the signal of the C4D.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemické listy
ISSN
0009-2770
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
S3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
2
Strana od-do
"S454"-"S455"
Kód UT WoS článku
000328730800069
EID výsledku v databázi Scopus
—