Popis výsledku v původním jazyce
Even though microorganisms are common part of our lives, some of them are dangerous and must be monitored. The traditional microbiological methods are reliable but slow. In some cases, namely in military, key requirement is fast detection which can be provided by biosensors. In this work, the piezoelectric biosensors providing fast, specific and cheap way of detection are described. Three strains of E. coli (BL21, DH5 alpha and K-12) were chosen as safe model microbes and the detection using the developed piezoelectric biosensor was carried out (LOD 10^6 CFU mL-1, total analysis time 20 min). Bioaerosol chamber was constructed to allow safe dissemination of microbes in air and experiments with bioaerosol. The generated bioaerosol was sampled using thecyclone air sampler and analyzed with the on-line coupled piezoelectric biosensor. The levels of 10^6 CFU L-1 of E.
Název v anglickém jazyce
Piezoelectric biosensor coupled to cyclone air sampler for detection of microorganisms
Popis výsledku anglicky
Even though microorganisms are common part of our lives, some of them are dangerous and must be monitored. The traditional microbiological methods are reliable but slow. In some cases, namely in military, key requirement is fast detection which can be provided by biosensors. In this work, the piezoelectric biosensors providing fast, specific and cheap way of detection are described. Three strains of E. coli (BL21, DH5 alpha and K-12) were chosen as safe model microbes and the detection using the developed piezoelectric biosensor was carried out (LOD 10^6 CFU mL-1, total analysis time 20 min). Bioaerosol chamber was constructed to allow safe dissemination of microbes in air and experiments with bioaerosol. The generated bioaerosol was sampled using thecyclone air sampler and analyzed with the on-line coupled piezoelectric biosensor. The levels of 10^6 CFU L-1 of E.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemické listy
ISSN
0009-2770
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
s3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
"s302"-"s304"
Kód UT WoS článku
000328730800008
EID výsledku v databázi Scopus
—