Revised relative potency values for PCDDs, PCDFs, and non-ortho-substituted PCBs for the optimized H4IIE-luc in vitro bioassay
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F13%3A00071147" target="_blank" >RIV/00216224:14310/13:00071147 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s11356-013-1770-2" target="_blank" >http://dx.doi.org/10.1007/s11356-013-1770-2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11356-013-1770-2" target="_blank" >10.1007/s11356-013-1770-2</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Revised relative potency values for PCDDs, PCDFs, and non-ortho-substituted PCBs for the optimized H4IIE-luc in vitro bioassay
Popis výsledku v původním jazyce
While the World Health Organization 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalency factors are useful estimates of relative potencies of mixtures when conducting risk assessments, they are not useful when comparing the results of bioassays such as the H4IIE-luc to concentrations of TCDD equivalents calculated from instrumental analyses. Since there are thousands of dioxin-like compounds (DLCs), one use of screening assays is to determine if all of the aryl hydrocarbon receptor (AhR) active DLCsin a mixture have been accounted for in instrumental analyses. For this purpose, bioassay-specific relative potency (ReP) values are needed. RePs of 21 polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls that exhibit effects mediated through the AhR were determined by use of the H4IIE-luc assay. Different values of RePs are derived, depending on the statistical, curve-fitting methods used to derive them from the dose-response relati
Název v anglickém jazyce
Revised relative potency values for PCDDs, PCDFs, and non-ortho-substituted PCBs for the optimized H4IIE-luc in vitro bioassay
Popis výsledku anglicky
While the World Health Organization 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalency factors are useful estimates of relative potencies of mixtures when conducting risk assessments, they are not useful when comparing the results of bioassays such as the H4IIE-luc to concentrations of TCDD equivalents calculated from instrumental analyses. Since there are thousands of dioxin-like compounds (DLCs), one use of screening assays is to determine if all of the aryl hydrocarbon receptor (AhR) active DLCsin a mixture have been accounted for in instrumental analyses. For this purpose, bioassay-specific relative potency (ReP) values are needed. RePs of 21 polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls that exhibit effects mediated through the AhR were determined by use of the H4IIE-luc assay. Different values of RePs are derived, depending on the statistical, curve-fitting methods used to derive them from the dose-response relati
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DN - Vliv životního prostředí na zdraví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0001%2F01%2F01" target="_blank" >ED0001/01/01: CETOCOEN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Environmental Science and Pollution Research
ISSN
0944-1344
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
8590-8599
Kód UT WoS článku
000327498600029
EID výsledku v databázi Scopus
—