Fast blood plasma separation device for point-of-care applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F18%3A00111646" target="_blank" >RIV/00216224:14310/18:00111646 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/18:00486643
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0039914018301127" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914018301127</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2018.02.004" target="_blank" >10.1016/j.talanta.2018.02.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast blood plasma separation device for point-of-care applications
Popis výsledku v původním jazyce
In this work, a simple device for extremely fast separation of blood plasma from diluted whole blood was developed. The device accommodates an asymmetric polysulfone membrane/supporting membrane sandwich that allows collection of 10 mu L blood plasma into a narrow glass capillary in less than 10 s. The composition of diluent solution was optimized in order to achieve maximum recoveries for selected metabolites of alcohol intoxication. 5% solution of [tris(hydroxymethyl)methylamino] propanesulfonic acid provided recoveries of formate, oxalate and glycolate close to 100% and only moderate erythrocyte lysis. Both charged and uncharged compounds from the whole blood samples can be analyzed in the separated blood plasma by capillary electrophoresis with contactless conductometric detection and spectrophotometry, respectively. The developed device might find wide application in on-site testing and point-of-care analysis, when only microliter volumes of whole blood are available.
Název v anglickém jazyce
Fast blood plasma separation device for point-of-care applications
Popis výsledku anglicky
In this work, a simple device for extremely fast separation of blood plasma from diluted whole blood was developed. The device accommodates an asymmetric polysulfone membrane/supporting membrane sandwich that allows collection of 10 mu L blood plasma into a narrow glass capillary in less than 10 s. The composition of diluent solution was optimized in order to achieve maximum recoveries for selected metabolites of alcohol intoxication. 5% solution of [tris(hydroxymethyl)methylamino] propanesulfonic acid provided recoveries of formate, oxalate and glycolate close to 100% and only moderate erythrocyte lysis. Both charged and uncharged compounds from the whole blood samples can be analyzed in the separated blood plasma by capillary electrophoresis with contactless conductometric detection and spectrophotometry, respectively. The developed device might find wide application in on-site testing and point-of-care analysis, when only microliter volumes of whole blood are available.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
1873-3573
Svazek periodika
183
Číslo periodika v rámci svazku
JUN
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
55-60
Kód UT WoS článku
000430645800008
EID výsledku v databázi Scopus
2-s2.0-85042222134