POTENTIAL OF EXHALED BREATH CONDENSATE ANALYSIS IN POINT OF CARE DIGNOSTICS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00081987" target="_blank" >RIV/00216224:14740/12:00081987 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
POTENTIAL OF EXHALED BREATH CONDENSATE ANALYSIS IN POINT OF CARE DIGNOSTICS
Popis výsledku v původním jazyce
Exhaled breath condensate has been analyzed for its ionic content by capillary electrophoresis with capacitively coupled contactless conductometric detection. Two devices for exhaled breath condensate collection were compared. These include a tube-in-tube cooled sampler and a simple zip-lock bag. The devices allow collection of small volumes (100-200 mu L) of exhaled breath condensate in less than 2 min. A method for quick (less than 3 min) simultaneous determination of inorganic cations, inorganic anions and organic anions from the samples using dual-opposite end injection principle with a short fused silica capillary (35 cm, 50 mu m i.d.) was optimized with final background electrolyte composition of 20 mM 2-(N-morpholino) ethanesulfonic acid, 20 mML-histidine, 30 mu M cetyltrimethylammonium bromide and 2 mM 18-crown-6 was used.
Název v anglickém jazyce
POTENTIAL OF EXHALED BREATH CONDENSATE ANALYSIS IN POINT OF CARE DIGNOSTICS
Popis výsledku anglicky
Exhaled breath condensate has been analyzed for its ionic content by capillary electrophoresis with capacitively coupled contactless conductometric detection. Two devices for exhaled breath condensate collection were compared. These include a tube-in-tube cooled sampler and a simple zip-lock bag. The devices allow collection of small volumes (100-200 mu L) of exhaled breath condensate in less than 2 min. A method for quick (less than 3 min) simultaneous determination of inorganic cations, inorganic anions and organic anions from the samples using dual-opposite end injection principle with a short fused silica capillary (35 cm, 50 mu m i.d.) was optimized with final background electrolyte composition of 20 mM 2-(N-morpholino) ethanesulfonic acid, 20 mML-histidine, 30 mu M cetyltrimethylammonium bromide and 2 mM 18-crown-6 was used.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2012: 9TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS
ISBN
9788090495913
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
128-133
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000329635000041