Statistical Analysis of Acquisition Parameters Variability and its Influence in Laser-Induced Breakdown Spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F15%3A00086564" target="_blank" >RIV/00216224:14740/15:00086564 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/15:PU117405
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Statistical Analysis of Acquisition Parameters Variability and its Influence in Laser-Induced Breakdown Spectroscopy
Popis výsledku v původním jazyce
The acquisition of laser induced plasma (LIP) is mostly preceded by an optimization of Laser- Induced Breakdown Spectroscopy (LIBS) analysis. The optimization is fine tuning of three main acquisition parameters (laser energy, gate delay and gate width) with respect to a required merit function. The merit function can be a single line intensity, signal to background ration or even more complicated calculations performed within measured spectra. This work concerns with variation of these basic acquisitionparameters and their influence on the resulting LIBS measurement, i.e. spectrum. It is possible to mathematically determine the minimal change in each parameter that results in statistically significant change in spectra or the merit function. Similar works concerned with the influence of the various parameters or with the proper statistic3 description of the resulting spectra, but not with the minimal change in acquisition parameters observable in the spectrum with respect to its natur
Název v anglickém jazyce
Statistical Analysis of Acquisition Parameters Variability and its Influence in Laser-Induced Breakdown Spectroscopy
Popis výsledku anglicky
The acquisition of laser induced plasma (LIP) is mostly preceded by an optimization of Laser- Induced Breakdown Spectroscopy (LIBS) analysis. The optimization is fine tuning of three main acquisition parameters (laser energy, gate delay and gate width) with respect to a required merit function. The merit function can be a single line intensity, signal to background ration or even more complicated calculations performed within measured spectra. This work concerns with variation of these basic acquisitionparameters and their influence on the resulting LIBS measurement, i.e. spectrum. It is possible to mathematically determine the minimal change in each parameter that results in statistically significant change in spectra or the merit function. Similar works concerned with the influence of the various parameters or with the proper statistic3 description of the resulting spectra, but not with the minimal change in acquisition parameters observable in the spectrum with respect to its natur
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů