Stanovení malondialdehydu v biologických vzorcích pomocí kapalinové chromatografie s ohledem na přípravu vzorku
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F05%3A00002830" target="_blank" >RIV/00216275:25310/05:00002830 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of malondialdehyde in biological samples using liquid chromatography with reference to sample preparation
Popis výsledku v původním jazyce
The most widely adopted method for valuation of oxidative stress is the estimation of the level of malondialdehyde (MDA), a stable product of the oxidative degradation of polyunsaturated fatty acids with more than two double bonds. This work refers to precise preparation of biological sample prior to HPLC analysis. Our method is based on the formation of the complex between MDA and 2-thiobarbituric acid (TBA). We have tested: effect of chelating agent on lipoperoxidation in vitro during derivatization step, different solvents for extraction of the MDA-TBA complex, and recovery of method. We found significantly increased levels of MDA in samples without addition of EDTA (1.11 +/- 0.18) umol/l, n = 69 vs. (0.72 +/- 0.13) umol/l, n = 69; Student's t test,alpha = 0.05, p < 0.001. Eight different solvents were tested: n-butanol, 1-propanol, 2-propanol, hexane, heptane, ethyl acetate, ethyl ether, and dichloromethane for extraction of the MDA-TBA complex. We found out, that only extraction
Název v anglickém jazyce
Determination of malondialdehyde in biological samples using liquid chromatography with reference to sample preparation
Popis výsledku anglicky
The most widely adopted method for valuation of oxidative stress is the estimation of the level of malondialdehyde (MDA), a stable product of the oxidative degradation of polyunsaturated fatty acids with more than two double bonds. This work refers to precise preparation of biological sample prior to HPLC analysis. Our method is based on the formation of the complex between MDA and 2-thiobarbituric acid (TBA). We have tested: effect of chelating agent on lipoperoxidation in vitro during derivatization step, different solvents for extraction of the MDA-TBA complex, and recovery of method. We found significantly increased levels of MDA in samples without addition of EDTA (1.11 +/- 0.18) umol/l, n = 69 vs. (0.72 +/- 0.13) umol/l, n = 69; Student's t test,alpha = 0.05, p < 0.001. Eight different solvents were tested: n-butanol, 1-propanol, 2-propanol, hexane, heptane, ethyl acetate, ethyl ether, and dichloromethane for extraction of the MDA-TBA complex. We found out, that only extraction
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Clin. Chim. Acta suppl.
ISBN
0009-8981
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
219
Název nakladatele
Elsevier
Místo vydání
UK
Místo konání akce
Glasgow, Skotsko
Datum konání akce
8. 5. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—