Stanovení kyseliny askorbové v lidské plazmě pomocí HPLC-UV s ohledem na stabilitu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F08%3A00007893" target="_blank" >RIV/00216275:25310/08:00007893 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of ascorbic acid in human plasma with a view to stability using HPLC with UV detection
Popis výsledku v původním jazyce
A method for the measurement of ascorbic acid using HPLC with UV detection and investigation into the protein precipitation techniques with regard to stability and recovery are described. The effectiveness of various protein precipitants was tested. Stability of ascorbic acid samples for analysis was investigated over 10 h. Ascorbic acid samples extracted with metaphosphoric acid were stable on a cooled autosampler (4 °C) for at least 10 h (with a decline of 1.8% for ascorbic acid solution and 2.8% forplasma). Perchloric acid as protein precipitant for ascorbic acid was unsuitable (with a decline of 36.0% for ascorbic acid solution and 7.3% for plasma). Analytical performance of this method is satisfactory. The intra- and interassay coefficients of variation were 2.1% (n = 10) and 5.8% (n = 12), respectively. The calibration curve was linear with the tested range of 2.0?250.0 umol/L. The recovery was 96.1% with CV = 4.8% (n = 6) and the LOD was 3 umol/L. The preliminary reference rang
Název v anglickém jazyce
Determination of ascorbic acid in human plasma with a view to stability using HPLC with UV detection
Popis výsledku anglicky
A method for the measurement of ascorbic acid using HPLC with UV detection and investigation into the protein precipitation techniques with regard to stability and recovery are described. The effectiveness of various protein precipitants was tested. Stability of ascorbic acid samples for analysis was investigated over 10 h. Ascorbic acid samples extracted with metaphosphoric acid were stable on a cooled autosampler (4 °C) for at least 10 h (with a decline of 1.8% for ascorbic acid solution and 2.8% forplasma). Perchloric acid as protein precipitant for ascorbic acid was unsuitable (with a decline of 36.0% for ascorbic acid solution and 7.3% for plasma). Analytical performance of this method is satisfactory. The intra- and interassay coefficients of variation were 2.1% (n = 10) and 5.8% (n = 12), respectively. The calibration curve was linear with the tested range of 2.0?250.0 umol/L. The recovery was 96.1% with CV = 4.8% (n = 6) and the LOD was 3 umol/L. The preliminary reference rang
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—