Continuous Dialysis of Hydrochloric Acid at Steady and Unsteady States
Popis výsledku v původním jazyce
The transport of hydrochloric acid through anion-exchange membrane Neosepta-AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution system - the overall dialysis coefficient and ermeability of the membrane - have been evaluated and compared at steady and unsteady states. The determination of these characteristics is based on the numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by the optimizing procedure. It was found, that the values of the overall dialysis coefficient determined from measurements at unsteady state are very similar to those obtained at steady state. The overall dialysis coefficient of hydrochloric acid shows strong increase with increasing acid concentration in the feed and weak increase with increasing volumetric flow rate. Moreover, in the concentration range of hydrochloric acid from 0.2 to 3.2 kmol m-3,
Název v anglickém jazyce
Continuous Dialysis of Hydrochloric Acid at Steady and Unsteady States
Popis výsledku anglicky
The transport of hydrochloric acid through anion-exchange membrane Neosepta-AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution system - the overall dialysis coefficient and ermeability of the membrane - have been evaluated and compared at steady and unsteady states. The determination of these characteristics is based on the numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by the optimizing procedure. It was found, that the values of the overall dialysis coefficient determined from measurements at unsteady state are very similar to those obtained at steady state. The overall dialysis coefficient of hydrochloric acid shows strong increase with increasing acid concentration in the feed and weak increase with increasing volumetric flow rate. Moreover, in the concentration range of hydrochloric acid from 0.2 to 3.2 kmol m-3,
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 34th International Conference of SSChE
ISBN
978-80-227-2640-5
ISSN
—
e-ISSN
—
Počet stran výsledku
13
Strana od-do
—
Název nakladatele
Slovak University of Technology in Bratislava
Místo vydání
Bratislava
Místo konání akce
Tatranské Matliare, SK
Datum konání akce
25. 5. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—