Kontinuální dialýza anorganických kyselin: Permeabilita membrány Neosepta-AFN
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F07%3A00006157" target="_blank" >RIV/00216275:25310/07:00006157 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuous Dialysis of Inorganic Acids: Permeability of Neosepta-AFN Membrane
Popis výsledku v původním jazyce
The transport of phosphoric and hydrochloric acids through anion-exchange membrane Neosepta AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution systems - the overall dialysis coefficient and the permeability of the membrane - have been evaluated at steady state. The determination of these characteristics is based on the numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by an optimizing procedure. It was found, that the permeability of membrane is strongly affected by acid concentration - for phosphoric acid it decreases with an increasing acid concentration and for hydrochloric acid it increases with an increasing acid concentration. Moreover, except for the lowest acid concentration used, the permeability for phosphoric acid is lower than that for hydrochloric acid - in the concentration range of acid from 0.2 to 3.0 kmol
Název v anglickém jazyce
Continuous Dialysis of Inorganic Acids: Permeability of Neosepta-AFN Membrane
Popis výsledku anglicky
The transport of phosphoric and hydrochloric acids through anion-exchange membrane Neosepta AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution systems - the overall dialysis coefficient and the permeability of the membrane - have been evaluated at steady state. The determination of these characteristics is based on the numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by an optimizing procedure. It was found, that the permeability of membrane is strongly affected by acid concentration - for phosphoric acid it decreases with an increasing acid concentration and for hydrochloric acid it increases with an increasing acid concentration. Moreover, except for the lowest acid concentration used, the permeability for phosphoric acid is lower than that for hydrochloric acid - in the concentration range of acid from 0.2 to 3.0 kmol
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the PERMEA 2007
ISBN
978-963-9319-69-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Hungarian Chemical Society
Místo vydání
Budapest
Místo konání akce
Siofok, Hungary
Datum konání akce
6. 9. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—