The transport of phosphoric and hydrochloric acids through anion-exchange membrane Neosepta AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution systems - the overall dialysis coefficient and the permeability of the membrane - have been evaluated at steady state. The determination of these characteristics is based on a numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by an optimizing procedure. It has been found that the permeability of the membrane is strongly affected by acid concentration - for phosphoric acid it decreases with an increasing acid concentration and for hydrochloric acidit increases with an increasing acid concentration. Moreover, except for the lowest acid concentration used, the permeability for phosphoric acid is lower than that for hydrochloric acid.
Název v anglickém jazyce
Continuous Dialysis of Inorganic Acids: Permeability of Neosepta-AFN Membrane
Popis výsledku anglicky
The transport of phosphoric and hydrochloric acids through anion-exchange membrane Neosepta AFN in a counter-current continuous dialyzer has been investigated. The basic transport characteristics of membrane/solution systems - the overall dialysis coefficient and the permeability of the membrane - have been evaluated at steady state. The determination of these characteristics is based on a numerical integration of the set of differential equations describing the concentration profiles in both compartments of the dialyzer followed by an optimizing procedure. It has been found that the permeability of the membrane is strongly affected by acid concentration - for phosphoric acid it decreases with an increasing acid concentration and for hydrochloric acidit increases with an increasing acid concentration. Moreover, except for the lowest acid concentration used, the permeability for phosphoric acid is lower than that for hydrochloric acid.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Desalination
ISSN
0011-9164
e-ISSN
—
Svazek periodika
240
Číslo periodika v rámci svazku
1-3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—