Regioisomeric Analysis of Triacylglycerols Using Silver-ion Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: Comparison of Five Different Mass Analyzers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F10%3A39881364" target="_blank" >RIV/00216275:25310/10:39881364 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388963:_____/10:00352178
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Regioisomeric Analysis of Triacylglycerols Using Silver-ion Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: Comparison of Five Different Mass Analyzers
Popis výsledku v původním jazyce
Silver-ion high-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization mass spectrometry (APCI-MS) is used for the regioisomeric analysis of triacylglycerols (TGs). In total, 32 different regioisomeric doublets and 11 triplets are synthesized, separated by silver-ion HPLC using three serial coupled chromatographic columns giving a total length of 75 cm. The retention of TGs increases strongly with the double bond (DB) number and slightly for regioisomers having moreDBs in sn-1/3 positions. DB positional isomers (linolenic vs. gama-linolenic acids) are also separated and their reverse retention order in two different mobile phases is demonstrated. APCI mass spectra of all separated regioisomers are measured on fivedifferent mass spectrometers: single quadrupole LC/MSD, triple quadrupole API 3000, ion trap Esquire 3000, quadrupole time-of-flight micrOTOF-Q and LTQ Orbitrap XL.
Název v anglickém jazyce
Regioisomeric Analysis of Triacylglycerols Using Silver-ion Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: Comparison of Five Different Mass Analyzers
Popis výsledku anglicky
Silver-ion high-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization mass spectrometry (APCI-MS) is used for the regioisomeric analysis of triacylglycerols (TGs). In total, 32 different regioisomeric doublets and 11 triplets are synthesized, separated by silver-ion HPLC using three serial coupled chromatographic columns giving a total length of 75 cm. The retention of TGs increases strongly with the double bond (DB) number and slightly for regioisomers having moreDBs in sn-1/3 positions. DB positional isomers (linolenic vs. gama-linolenic acids) are also separated and their reverse retention order in two different mobile phases is demonstrated. APCI mass spectra of all separated regioisomers are measured on fivedifferent mass spectrometers: single quadrupole LC/MSD, triple quadrupole API 3000, ion trap Esquire 3000, quadrupole time-of-flight micrOTOF-Q and LTQ Orbitrap XL.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F09%2F0139" target="_blank" >GA203/09/0139: Komplexní lipidomická charakterizace rostlinných a živočišných tkání</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1217
Číslo periodika v rámci svazku
52
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000285899400014
EID výsledku v databázi Scopus
—