Possibilities of retention prediction in fast gradient liquid chromatography. Part 3: Short silica monolithic columns
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900220" target="_blank" >RIV/00216275:25310/15:39900220 - isvavai.cz</a>
Výsledek na webu
<a href="http://apps.webofknowledge.com/full_record.do?product=UA&search_mode=GeneralSearch&qid=2&SID=Z2XMp3XcgGvozkUKLG2&page=1&doc=1" target="_blank" >http://apps.webofknowledge.com/full_record.do?product=UA&search_mode=GeneralSearch&qid=2&SID=Z2XMp3XcgGvozkUKLG2&page=1&doc=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2015.07.070" target="_blank" >10.1016/j.chroma.2015.07.070</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Possibilities of retention prediction in fast gradient liquid chromatography. Part 3: Short silica monolithic columns
Popis výsledku v původním jazyce
We studied possibilities of prediction of the gradient elution data for alkylbenzenes, flavones and phenolic acids on two short octadecyl silica gel monolithic columns, namely a Chromolith Flash C18, 25 x 4.6 mm, and a "new generation" Chromolith High Resolution C18, 50 x 4.6 mm, in fast 1-2 min gradients. With fixed short gradient times and varying gradient ranges of acetonitrile concentration in water, high flow rates of the mobile phase (3-5 mL/min) could be used. The gradient elution data were predicted from four gradient models based on two-parameter and three-parameter isocratic retention equations. Various gradient retention models can be used for prediction of chromatograms and optimization of separation within a fixed gradient time. A two-parameter log log model introduced in 1974 and a three-parameter model introduced in 1980 provided slightly more accurate prediction than the Linear Solvent Strength (LSS) semi-logarithmic two-parameter model, most frequently used in reversed
Název v anglickém jazyce
Possibilities of retention prediction in fast gradient liquid chromatography. Part 3: Short silica monolithic columns
Popis výsledku anglicky
We studied possibilities of prediction of the gradient elution data for alkylbenzenes, flavones and phenolic acids on two short octadecyl silica gel monolithic columns, namely a Chromolith Flash C18, 25 x 4.6 mm, and a "new generation" Chromolith High Resolution C18, 50 x 4.6 mm, in fast 1-2 min gradients. With fixed short gradient times and varying gradient ranges of acetonitrile concentration in water, high flow rates of the mobile phase (3-5 mL/min) could be used. The gradient elution data were predicted from four gradient models based on two-parameter and three-parameter isocratic retention equations. Various gradient retention models can be used for prediction of chromatograms and optimization of separation within a fixed gradient time. A two-parameter log log model introduced in 1974 and a three-parameter model introduced in 1980 provided slightly more accurate prediction than the Linear Solvent Strength (LSS) semi-logarithmic two-parameter model, most frequently used in reversed
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1410
Číslo periodika v rámci svazku
July 2015
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
14
Strana od-do
76-89
Kód UT WoS článku
000360415900010
EID výsledku v databázi Scopus
—