Sensitive voltammetric method for the fast analysis of the Sunagreen using a boron doped diamond electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F16%3A39901437" target="_blank" >RIV/00216275:25310/16:39901437 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitive voltammetric method for the fast analysis of the Sunagreen using a boron doped diamond electrode
Popis výsledku v původním jazyce
A voltammetric method has been developed for the determination of a mixture of 2MINUS SIGN aminobenzoic acid and 2MINUS SIGN hydroxybenzoic acid that both are present in the Sunagreen fortmulation used as a plants growth stimulator. After opzimization of the key experimental and instrumental conditions, linear sweep voltammetry mode was chosen to determine both main substances and combined with a boron-doped diamond electrode in the role of convenient working electrode. Specially, in this work, a new mathematical algorithm was proposed serving to evaluate the respective voltammetric current signals that had originally been nonlinear with concentration. Limits of detection (LODs) for 2-aminobenzoic acid and 2-hydroxybenzoic acid were estimated to be 5.24 mol L-1 and 7.0 mol L-1, resp. Finally, selected real samples were anaylyzed and the results obtained agreed well with the declared values.
Název v anglickém jazyce
Sensitive voltammetric method for the fast analysis of the Sunagreen using a boron doped diamond electrode
Popis výsledku anglicky
A voltammetric method has been developed for the determination of a mixture of 2MINUS SIGN aminobenzoic acid and 2MINUS SIGN hydroxybenzoic acid that both are present in the Sunagreen fortmulation used as a plants growth stimulator. After opzimization of the key experimental and instrumental conditions, linear sweep voltammetry mode was chosen to determine both main substances and combined with a boron-doped diamond electrode in the role of convenient working electrode. Specially, in this work, a new mathematical algorithm was proposed serving to evaluate the respective voltammetric current signals that had originally been nonlinear with concentration. Limits of detection (LODs) for 2-aminobenzoic acid and 2-hydroxybenzoic acid were estimated to be 5.24 mol L-1 and 7.0 mol L-1, resp. Finally, selected real samples were anaylyzed and the results obtained agreed well with the declared values.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVI Moderní elektrochemické metody
ISBN
978-80-905221-4-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
81-85
Název nakladatele
BEST Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
23. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000389898200019