Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39910930" target="_blank" >RIV/00216275:25310/17:39910930 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s11696-017-0135-6" target="_blank" >http://dx.doi.org/10.1007/s11696-017-0135-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11696-017-0135-6" target="_blank" >10.1007/s11696-017-0135-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode
Popis výsledku v původním jazyce
Voltammetric method for the determination of non-steroidal anti-inflammatory drug mesalazine (5-ASA) is presented for the first time using boron-doped diamond electrode (BDDE). 5-ASA provides one well-developed SWV oxidation peak at about -900 mV (vs. saturated silver/silver chloride reference electrode) on BDDE. Britton-Robinson buffer (pH 7.0) was chosen as an optimal supporting electrolyte for the determination of 5-ASA using square wave voltammetry (SWV). Parameters of SWV were developed and low limit of detection (7.0 9 10-7 mol L-1) was reached. In addition, relative standard deviation of repeated measurements (c5-ASA = 5 9 10-5 mol L-1, RSDM = 2.7%) and relative standard deviation of repeated determinations (RSDD 1.5%) were calculated and confirm obtained good results. Applicability of the proposed method was verified by an analysis of a pharmaceutical preparation and spiked human urine.
Název v anglickém jazyce
Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode
Popis výsledku anglicky
Voltammetric method for the determination of non-steroidal anti-inflammatory drug mesalazine (5-ASA) is presented for the first time using boron-doped diamond electrode (BDDE). 5-ASA provides one well-developed SWV oxidation peak at about -900 mV (vs. saturated silver/silver chloride reference electrode) on BDDE. Britton-Robinson buffer (pH 7.0) was chosen as an optimal supporting electrolyte for the determination of 5-ASA using square wave voltammetry (SWV). Parameters of SWV were developed and low limit of detection (7.0 9 10-7 mol L-1) was reached. In addition, relative standard deviation of repeated measurements (c5-ASA = 5 9 10-5 mol L-1, RSDM = 2.7%) and relative standard deviation of repeated determinations (RSDD 1.5%) were calculated and confirm obtained good results. Applicability of the proposed method was verified by an analysis of a pharmaceutical preparation and spiked human urine.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
0366-6352
e-ISSN
—
Svazek periodika
71
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
1419-1427
Kód UT WoS článku
000405694900005