Flow injection tyrosinase biosensor for direct determination of acetaminophen in human urine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914601" target="_blank" >RIV/00216275:25310/19:39914601 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00216-019-01687-4" target="_blank" >https://link.springer.com/article/10.1007/s00216-019-01687-4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-019-01687-4" target="_blank" >10.1007/s00216-019-01687-4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow injection tyrosinase biosensor for direct determination of acetaminophen in human urine
Popis výsledku v původním jazyce
An amperometric biosensor compatible with a flow injection analysis (FIA) for highly selective determination of acetaminophen (APAP) in a sample of human urine was developed. This biosensor is also suitable for use in the routine pharmaceutical practice. To prove this statement, two different commercially available pharmaceutical formulations were analyzed. This nano-(bio)electroanalytical device was made from a commercially available screen-printed carbon electrode covered by a thin layer of non-functionalized graphene (NFG) as amperometric transducer. A biorecognition layer was prepared from mushroom (Agaricus bisporus) tyrosinase (EC 1.14.18.1) cross-linked using glutaraldehyde, where resulting aggregates were covered by Nafion (R), a known ion exchange membrane. Owing to the use of tyrosinase and presence of NFG, the developed analytical instrument is able to measure even at potentials of 0 V. Linear ranges differ according to choice of detection potential, namely up to 130 mu mol L-1 at 0 V, up to 90 mu mol L-1 at -0.1 V, and up to 70 mu mol L-1 at -0.15 V. The first mentioned linear range is described by the equation I-p [mu A] = 0.236-0.1984c [mu mol L-1] and correlation coefficient r = 0.9987; this equation was used to quantify the content of APAP in each sample. The limit of detection of APAP was estimated to be 1.1 mu mol L-1. A recovery of 96.8% (c = 25 mu mol L-1, n = 5 measurements) was calculated. The obtained results show that FIA is a very selective method for APAP determination, being comparable to the chosen reference method of reversed-phase high-performance liquid chromatography.
Název v anglickém jazyce
Flow injection tyrosinase biosensor for direct determination of acetaminophen in human urine
Popis výsledku anglicky
An amperometric biosensor compatible with a flow injection analysis (FIA) for highly selective determination of acetaminophen (APAP) in a sample of human urine was developed. This biosensor is also suitable for use in the routine pharmaceutical practice. To prove this statement, two different commercially available pharmaceutical formulations were analyzed. This nano-(bio)electroanalytical device was made from a commercially available screen-printed carbon electrode covered by a thin layer of non-functionalized graphene (NFG) as amperometric transducer. A biorecognition layer was prepared from mushroom (Agaricus bisporus) tyrosinase (EC 1.14.18.1) cross-linked using glutaraldehyde, where resulting aggregates were covered by Nafion (R), a known ion exchange membrane. Owing to the use of tyrosinase and presence of NFG, the developed analytical instrument is able to measure even at potentials of 0 V. Linear ranges differ according to choice of detection potential, namely up to 130 mu mol L-1 at 0 V, up to 90 mu mol L-1 at -0.1 V, and up to 70 mu mol L-1 at -0.15 V. The first mentioned linear range is described by the equation I-p [mu A] = 0.236-0.1984c [mu mol L-1] and correlation coefficient r = 0.9987; this equation was used to quantify the content of APAP in each sample. The limit of detection of APAP was estimated to be 1.1 mu mol L-1. A recovery of 96.8% (c = 25 mu mol L-1, n = 5 measurements) was calculated. The obtained results show that FIA is a very selective method for APAP determination, being comparable to the chosen reference method of reversed-phase high-performance liquid chromatography.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
411
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
2415-2424
Kód UT WoS článku
000464715500016
EID výsledku v databázi Scopus
—