Voltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10125455" target="_blank" >RIV/00216208:11310/12:10125455 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2478/s11532-012-0056-8" target="_blank" >http://dx.doi.org/10.2478/s11532-012-0056-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/s11532-012-0056-8" target="_blank" >10.2478/s11532-012-0056-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrode
Popis výsledku v původním jazyce
New methods for the determination of metoclopramide, antiemetic and gastroprokinetic pharmaceutical, were developed, using differential pulse voltammetry (DPV) and flow injection analysis (FIA) with amperometric detection on a boron-doped diamond film electrode. Electrode pretreatment necessary to ensure the stable results was investigated and it was found, that while DPV requires frequent electrode cleaning, FIA with a sufficiently high flow rate can maintain a stable signal with no signs of electrodepassivation. The calculated quantification limits of the DPV and FIA with amperometric detection were 0.13 mu mol L-1 and 0.015 mmol L-1, respectively. The applicability of the new methods was verified by the determination of metoclopramide in a pharmaceutical preparation. FIA with amperometic detection proved to be sensitive, accurate and, due to the resistance of the electrode to the passivation, also simple to handle.
Název v anglickém jazyce
Voltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrode
Popis výsledku anglicky
New methods for the determination of metoclopramide, antiemetic and gastroprokinetic pharmaceutical, were developed, using differential pulse voltammetry (DPV) and flow injection analysis (FIA) with amperometric detection on a boron-doped diamond film electrode. Electrode pretreatment necessary to ensure the stable results was investigated and it was found, that while DPV requires frequent electrode cleaning, FIA with a sufficiently high flow rate can maintain a stable signal with no signs of electrodepassivation. The calculated quantification limits of the DPV and FIA with amperometric detection were 0.13 mu mol L-1 and 0.015 mmol L-1, respectively. The applicability of the new methods was verified by the determination of metoclopramide in a pharmaceutical preparation. FIA with amperometic detection proved to be sensitive, accurate and, due to the resistance of the electrode to the passivation, also simple to handle.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1895-1066
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
1310-1317
Kód UT WoS článku
000304618900035