The First Study of the Electrochemical Behavior of Mephenoxalone and its Determination Using Screen-Printed Sensors With Chemically Deposited Boron Doped Diamond Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F21%3A39917763" target="_blank" >RIV/00216275:25310/21:39917763 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The First Study of the Electrochemical Behavior of Mephenoxalone and its Determination Using Screen-Printed Sensors With Chemically Deposited Boron Doped Diamond Electrode
Popis výsledku v původním jazyce
Electrochemical oxidation of a mephenoxalone (MNL) was firstly studied using boron doped diamond electrode (BDDE). At different pH, an irreversible anodic peak was observed at potential of +1.375 V (vs. Ag/AgCl). The voltammetric method for MNL determination was developed using square wave voltammetry. This method provides low limit of detection (5.5×10–8 mol L–1), wide linear dynamic range (1.0×10–7-3.0×10–5 mol L–1), and good recovery in the analysis of model samples as well as pharmaceutical preparation Dimexol 200 mg. The developed method was successfully transferred to the commercially available and lab-made screen-printed sensors with chemically deposited BDDE.
Název v anglickém jazyce
The First Study of the Electrochemical Behavior of Mephenoxalone and its Determination Using Screen-Printed Sensors With Chemically Deposited Boron Doped Diamond Electrode
Popis výsledku anglicky
Electrochemical oxidation of a mephenoxalone (MNL) was firstly studied using boron doped diamond electrode (BDDE). At different pH, an irreversible anodic peak was observed at potential of +1.375 V (vs. Ag/AgCl). The voltammetric method for MNL determination was developed using square wave voltammetry. This method provides low limit of detection (5.5×10–8 mol L–1), wide linear dynamic range (1.0×10–7-3.0×10–5 mol L–1), and good recovery in the analysis of model samples as well as pharmaceutical preparation Dimexol 200 mg. The developed method was successfully transferred to the commercially available and lab-made screen-printed sensors with chemically deposited BDDE.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-01589S" target="_blank" >GA20-01589S: Nové strategie pro zlepšení senzorových vlastností nových elektrodových materiálů prostřednictvím jejich předúpravy či modifikace povrchu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XL. Moderní elektrochemické metody : sborník přednášek
ISBN
978-80-905221-8-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
159-163
Název nakladatele
BEST Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
8. 11. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—