Electrochemical oxidation of anti-inflammatory drug meloxicam and its determination using boron doped diamond electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F20%3A73603855" target="_blank" >RIV/61989592:15310/20:73603855 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25310/20:39916369
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1572665719310264" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1572665719310264</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jelechem.2019.113758" target="_blank" >10.1016/j.jelechem.2019.113758</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical oxidation of anti-inflammatory drug meloxicam and its determination using boron doped diamond electrode
Popis výsledku v původním jazyce
Voltammetric behavior of a nonsteroidal anti-inflammatory drug meloxicam was firstly studied using boron doped diamond electrode (BDDE). Two irreversible anodic current peaks were observed in wide pH range at potentials +900 mV and +1400 mV vs. saturated silver-silver chloride electrode. Mechanism of the electrochemical oxidation was proposed and confirmed using high performance liquid chromatography/mass spectrometry analysis of electrolyzed meloxicam solutions. Subsequently, an analytical method for meloxicam determination was developed using differential pulse voltammetry in connection with BDDE. This method provides low limit of detection (5.9 x 10(-8) mol L-1) and wide linear dynamic range (2.5 x 10(-7)-8.5 x 10(-5) mol L-1). Finally, model solutions as well as pharmaceutical preparations were successfully analyzed, and the meloxicam content was determined.
Název v anglickém jazyce
Electrochemical oxidation of anti-inflammatory drug meloxicam and its determination using boron doped diamond electrode
Popis výsledku anglicky
Voltammetric behavior of a nonsteroidal anti-inflammatory drug meloxicam was firstly studied using boron doped diamond electrode (BDDE). Two irreversible anodic current peaks were observed in wide pH range at potentials +900 mV and +1400 mV vs. saturated silver-silver chloride electrode. Mechanism of the electrochemical oxidation was proposed and confirmed using high performance liquid chromatography/mass spectrometry analysis of electrolyzed meloxicam solutions. Subsequently, an analytical method for meloxicam determination was developed using differential pulse voltammetry in connection with BDDE. This method provides low limit of detection (5.9 x 10(-8) mol L-1) and wide linear dynamic range (2.5 x 10(-7)-8.5 x 10(-5) mol L-1). Finally, model solutions as well as pharmaceutical preparations were successfully analyzed, and the meloxicam content was determined.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ELECTROANALYTICAL CHEMISTRY
ISSN
1572-6657
e-ISSN
—
Svazek periodika
858
Číslo periodika v rámci svazku
FEB
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
"113758-1"-"113758-9"
Kód UT WoS článku
000515205600004
EID výsledku v databázi Scopus
2-s2.0-85076893090