Parametric Study of Air Flow Shape in Saddleback Double-Cladding Ventilated Roof on Input Velocity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU107517" target="_blank" >RIV/00216305:26110/14:PU107517 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.871.45" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.871.45</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.871.45" target="_blank" >10.4028/www.scientific.net/AMR.871.45</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Parametric Study of Air Flow Shape in Saddleback Double-Cladding Ventilated Roof on Input Velocity
Popis výsledku v původním jazyce
The study of air flow and its modelling is particularly focused on designing double-cladding roofs, which are recommended for buildings in wet conditions. Software ANSYS, which uses CFD method, is used for the modelling. The primary issue concerning the design of ventilated double-cladding roofs is to select the optimum thickness of air cavity. The study shows that the shape of streamlines in the ventilated cavity of a double-cladding flat saddleback roof is not based on the input velocity. Based on the selected model, there is a blind spot in between 1.76 m and 4.23 m of the outer edge of the attic where air back flow occurs at the bottom surface of the upper roof deck which leads to poor ventilation of the ventilated cavity.
Název v anglickém jazyce
Parametric Study of Air Flow Shape in Saddleback Double-Cladding Ventilated Roof on Input Velocity
Popis výsledku anglicky
The study of air flow and its modelling is particularly focused on designing double-cladding roofs, which are recommended for buildings in wet conditions. Software ANSYS, which uses CFD method, is used for the modelling. The primary issue concerning the design of ventilated double-cladding roofs is to select the optimum thickness of air cavity. The study shows that the shape of streamlines in the ventilated cavity of a double-cladding flat saddleback roof is not based on the input velocity. Based on the selected model, there is a blind spot in between 1.76 m and 4.23 m of the outer edge of the attic where air back flow occurs at the bottom surface of the upper roof deck which leads to poor ventilation of the ventilated cavity.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EnviBUILD Buildings and Environment 2013
ISBN
978-3-03835-040-8
ISSN
1022-6680
e-ISSN
1662-8985
Počet stran výsledku
5
Strana od-do
45-49
Název nakladatele
Trans Tech Publications
Místo vydání
Switzerland
Místo konání akce
Bratislava
Datum konání akce
17. 10. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce