Návrh částí myoelektrické ruční protézy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F04%3APU43600" target="_blank" >RIV/00216305:26210/04:PU43600 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DESIGN OF MECHANICAL PART OF THE MYOELECTRIC HAND PROSHESIS
Popis výsledku v původním jazyce
A myolectric hand prosthesis for practical application is being developed as part of a doctoral study at the Brno Technical University, Faculty of Mechanical Engineering, Department of Production Machines, Systems and Robotics. Commercially available myoelectric hand prostheses only allow for non-adaptive gripping of an object with three fingers each of them having one degree of freedom. The prosthesis is controlled by means of myosignals, being low voltage electric pulses measurable on the skin of manarising through muscle contraction or through contraction effected by muscles. The prosthesis developed in the above Faculty should feature parameters comparable to commercially available aids, i.e. gripping force min. 50 N, yaw min. 100 mm, finger closing time less than 1.5 s, prosthesis weight max. 500 g. However, in contrast to ordinary prosthesis it will be capable of adaptable gripping of an object between two fingers (each having 3 degrees of freedom) and a thumb using the two most
Název v anglickém jazyce
DESIGN OF MECHANICAL PART OF THE MYOELECTRIC HAND PROSHESIS
Popis výsledku anglicky
A myolectric hand prosthesis for practical application is being developed as part of a doctoral study at the Brno Technical University, Faculty of Mechanical Engineering, Department of Production Machines, Systems and Robotics. Commercially available myoelectric hand prostheses only allow for non-adaptive gripping of an object with three fingers each of them having one degree of freedom. The prosthesis is controlled by means of myosignals, being low voltage electric pulses measurable on the skin of manarising through muscle contraction or through contraction effected by muscles. The prosthesis developed in the above Faculty should feature parameters comparable to commercially available aids, i.e. gripping force min. 50 N, yaw min. 100 mm, finger closing time less than 1.5 s, prosthesis weight max. 500 g. However, in contrast to ordinary prosthesis it will be capable of adaptable gripping of an object between two fingers (each having 3 degrees of freedom) and a thumb using the two most
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings - 13th International Workshop on RAAD
ISBN
80-7204-341-2
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
143-145
Název nakladatele
VUT-Brno
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
1. 6. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—