Korelace akustických a optických signálů při 1064 nm a 532 nm laserové ablace glazovaných dláždic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F08%3APU77696" target="_blank" >RIV/00216305:26210/08:PU77696 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/09:00034527
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles
Popis výsledku v původním jazyce
An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite differentirradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.
Název v anglickém jazyce
Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles
Popis výsledku anglicky
An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite differentirradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Spectrochimica Acta Part B
ISSN
0584-8547
e-ISSN
—
Svazek periodika
XXX
Číslo periodika v rámci svazku
SAB-03892
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—