Dynamical Deformation Compensation of Phase in Digital Holographic Microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F10%3APU91094" target="_blank" >RIV/00216305:26210/10:PU91094 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamical Deformation Compensation of Phase in Digital Holographic Microscopy
Popis výsledku v původním jazyce
Digital holographic microscopy (DHM) is a powerful tool for observation of biological samples. The main advantage of DHM imaging is the possibility to reconstruct the intensity image and the phase image of an observed sample in real-time. The backgroundof phase images is deformed and this deformation is changing during a long-term experiment. We describe here a novel procedure of deformation compensation for sequence of phase images. This novel procedure is based on deformation compensation procedure for a single phase image which uses the least square method. The novel procedure is applicable to compensate deformation during observation in real-time. The proposed procedure is applied to phase images of cells obtained by a transmitted-light digital holographic microscope.
Název v anglickém jazyce
Dynamical Deformation Compensation of Phase in Digital Holographic Microscopy
Popis výsledku anglicky
Digital holographic microscopy (DHM) is a powerful tool for observation of biological samples. The main advantage of DHM imaging is the possibility to reconstruct the intensity image and the phase image of an observed sample in real-time. The backgroundof phase images is deformed and this deformation is changing during a long-term experiment. We describe here a novel procedure of deformation compensation for sequence of phase images. This novel procedure is based on deformation compensation procedure for a single phase image which uses the least square method. The novel procedure is applicable to compensate deformation during observation in real-time. The proposed procedure is applied to phase images of cells obtained by a transmitted-light digital holographic microscope.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F08%2F0590" target="_blank" >GA202/08/0590: Využití digitálního holografického mikroskopu pro výzkum dynamiky živé buňky a dovršení vývoje nového multifunkčního mikroskopu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th. Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics, Liptovský Ján, september 2010,
ISBN
978-80-554-0238-3
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Lipt. Ján
Datum konání akce
6. 9. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—