Biomechanical indices are more sensitive than diameter in predicting rupture of asymptomatic abdominal aortic aneurysms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F20%3APU137613" target="_blank" >RIV/00216305:26210/20:PU137613 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/19:00071730 RIV/00216224:14110/20:00115438 RIV/00216208:11110/20:10411166 RIV/61989100:27230/19:10242473 RIV/00064165:_____/20:10411166
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0741521419310377?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0741521419310377?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jvs.2019.03.051" target="_blank" >10.1016/j.jvs.2019.03.051</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical indices are more sensitive than diameter in predicting rupture of asymptomatic abdominal aortic aneurysms
Popis výsledku v původním jazyce
Objective: Several studies of biomechanical rupture risk assessment (BRRA) showed its advantage over the diameter criterion in rupture risk assessment of abdominal aortic aneurysm (AAA). However, BRRA studies have not investigated the predictability of biomechanical risk indices at different time points ahead of rupture, nor have they been performed blinded for biomechanical analysts. The objective of this study was to test the predictability of the BRRA method against diameter-based risk indices in a quasi-prospective patient cohort study. Methods: In total, 12 women and 31 men with intact AAAs at baseline have been selected retrospectively at two medical centers. Within 56 months, 19 cases ruptured, whereas 24 cases remained intact within 2 to 56 months. This outcome was kept confidential until all biomechanical activities in this study were finished. The biomechanical AAA rupture risk was calculated at baseline using high-fidelity and low-fidelity finite element method models. The capability of biomechanics-based and diameter-based risk indices to predict the known outcomes at 1 month, 3 months, 6 months, 9 months, and 12 months after baseline was validated. Besides common cohort statistics, the area under the curve (AUC) of receiver operating characteristic curves has been used to grade the different rupture risk indices. Results: Up to 9 months ahead of rupture, the receiver operating characteristic analysis of biomechanics-based risk indices showed a higher AUC than diameter-based indices. Six months ahead of rupture, the largest difference was observed with an AUC of 0.878 for the high-fidelity biomechanical risk index, 0.859 for the low-fidelity biomechanical risk index, 0.789 for the diameter, and 0.821 for the sex-adjusted diameter. In predictions beyond 9 months, none of the risk indices proved to be superior. Conclusions: High-fidelity biomechanical modeling improves the predictability of AAA rupture. Asymptomatic AAA patients with high biomechanical
Název v anglickém jazyce
Biomechanical indices are more sensitive than diameter in predicting rupture of asymptomatic abdominal aortic aneurysms
Popis výsledku anglicky
Objective: Several studies of biomechanical rupture risk assessment (BRRA) showed its advantage over the diameter criterion in rupture risk assessment of abdominal aortic aneurysm (AAA). However, BRRA studies have not investigated the predictability of biomechanical risk indices at different time points ahead of rupture, nor have they been performed blinded for biomechanical analysts. The objective of this study was to test the predictability of the BRRA method against diameter-based risk indices in a quasi-prospective patient cohort study. Methods: In total, 12 women and 31 men with intact AAAs at baseline have been selected retrospectively at two medical centers. Within 56 months, 19 cases ruptured, whereas 24 cases remained intact within 2 to 56 months. This outcome was kept confidential until all biomechanical activities in this study were finished. The biomechanical AAA rupture risk was calculated at baseline using high-fidelity and low-fidelity finite element method models. The capability of biomechanics-based and diameter-based risk indices to predict the known outcomes at 1 month, 3 months, 6 months, 9 months, and 12 months after baseline was validated. Besides common cohort statistics, the area under the curve (AUC) of receiver operating characteristic curves has been used to grade the different rupture risk indices. Results: Up to 9 months ahead of rupture, the receiver operating characteristic analysis of biomechanics-based risk indices showed a higher AUC than diameter-based indices. Six months ahead of rupture, the largest difference was observed with an AUC of 0.878 for the high-fidelity biomechanical risk index, 0.859 for the low-fidelity biomechanical risk index, 0.789 for the diameter, and 0.821 for the sex-adjusted diameter. In predictions beyond 9 months, none of the risk indices proved to be superior. Conclusions: High-fidelity biomechanical modeling improves the predictability of AAA rupture. Asymptomatic AAA patients with high biomechanical
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-16304S" target="_blank" >GA13-16304S: Predikce ruptury výdutě břišní aorty na základě výpočtového modelování</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF VASCULAR SURGERY
ISSN
0741-5214
e-ISSN
1097-6809
Svazek periodika
71
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
„617“-„+“
Kód UT WoS článku
000508630800037
EID výsledku v databázi Scopus
2-s2.0-85066496556