Environmental scanning electron microscope (ESEM) allows the visualisation of specimens that are difficult or impossible to image in a conventional high vacuum SEM. Pressure in the specimen chamber ranges from 1 Pa over 2000 Pa, which permits to observespecimens of beeing free from charging artefacts and containing different volume of water. But there are some difficulties with the observation of highly wet biological specimens in their natural state because during a pre-pumping process of the specimenn chamber an escape of water from the specimen occurs and thus its surface is damaged. The aim of this contribution is to find a method making possible to decrease water escape from the specimen during the initiation pumping process of the ESEM, immediately after the inserting of the specimen into the specimen chamber and during an image recording.
Název v anglickém jazyce
Influence of water environment on biological specimens imaging in ESEM
Popis výsledku anglicky
Environmental scanning electron microscope (ESEM) allows the visualisation of specimens that are difficult or impossible to image in a conventional high vacuum SEM. Pressure in the specimen chamber ranges from 1 Pa over 2000 Pa, which permits to observespecimens of beeing free from charging artefacts and containing different volume of water. But there are some difficulties with the observation of highly wet biological specimens in their natural state because during a pre-pumping process of the specimenn chamber an escape of water from the specimen occurs and thus its surface is damaged. The aim of this contribution is to find a method making possible to decrease water escape from the specimen during the initiation pumping process of the ESEM, immediately after the inserting of the specimen into the specimen chamber and during an image recording.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F01%2F1271" target="_blank" >GA102/01/1271: Studium detekčních metod a systémů v hraničních podmínkách environmentální rastrovací elektronové mikroskopie</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings 6th Multinational Congress on Microscopy
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
497-498
Název nakladatele
—
Místo vydání
Pula
Místo konání akce
Pula
Datum konání akce
1. 6. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—