Current density distribution, noise and non-linearity of thick film resistors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F03%3APU40392" target="_blank" >RIV/00216305:26220/03:PU40392 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Current density distribution, noise and non-linearity of thick film resistors
Popis výsledku v původním jazyce
The noise spectroscopy and third harmonic measurements were used to investigate effect of the contact electrode material on the thick film resistor quality and reliability. Strong dependence of nonlinearity on the contact electrode material wasobserved.Thick film resistors with AgPd contactelectrode have higher value of third harmonic voltage,but show better long term stability and reliabilitycomparing with resistors with Ag contact electrode.From the SEM figures we determined, that the sharpness of AggPd contact electrode is approximately 7deg, while Ag contact electrode sharpness is approx. 12deg. It was proved experimentally that noise spectraldensity is proportional to electric field intensity, whilethird harmonic voltage depends on the third power ofelectric field intensity or current density. Modelling ofthe current distribution for two different shapes of metallic contact cross sections was performed. The model shows that the electrode geometry plays dominant role for current d
Název v anglickém jazyce
Current density distribution, noise and non-linearity of thick film resistors
Popis výsledku anglicky
The noise spectroscopy and third harmonic measurements were used to investigate effect of the contact electrode material on the thick film resistor quality and reliability. Strong dependence of nonlinearity on the contact electrode material wasobserved.Thick film resistors with AgPd contactelectrode have higher value of third harmonic voltage,but show better long term stability and reliabilitycomparing with resistors with Ag contact electrode.From the SEM figures we determined, that the sharpness of AggPd contact electrode is approximately 7deg, while Ag contact electrode sharpness is approx. 12deg. It was proved experimentally that noise spectraldensity is proportional to electric field intensity, whilethird harmonic voltage depends on the third power ofelectric field intensity or current density. Modelling ofthe current distribution for two different shapes of metallic contact cross sections was performed. The model shows that the electrode geometry plays dominant role for current d
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Capacitor and Resistor Technology
ISSN
0887-7491
e-ISSN
—
Svazek periodika
2003
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
112-116