Ultrasonografické zobrazování s vysokou rozlišovací schopností pomocí rychlé 2-D homomorfické filtrace
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU64069" target="_blank" >RIV/00216305:26220/06:PU64069 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Resolution Ultrasonic Imaging Using Fast Two-Dimensional Homomorphic Filtering
Popis výsledku v původním jazyce
A new method for two-dimensional deconvolution of medical ultrasonic images is presented. The spatial resolution of the deconvolved images is much higher compared to the common images of the fundamental and second harmonic. The deconvolution also resultsin a more distinct speckle pattern. Unlike the most published deconvolution algorithms for ultrasonic images, the presented technique can be implemented using currently available hardware in real-time imaging, with rate up to 50 frames per second. Thismakes it attractive for application in the current ultrasound scanners. The algorithm is based on two-dimensional homomorphic deconvolution with simplified assumptions about the point spread function. Broadband radiofrequency image data are deconvolved instead of common fundamental-harmonic data. Thus, information of both the first and second harmonics is used. The method was validated on image data recorded from a tissue-mimicking phantom and on clinical image data.
Název v anglickém jazyce
High-Resolution Ultrasonic Imaging Using Fast Two-Dimensional Homomorphic Filtering
Popis výsledku anglicky
A new method for two-dimensional deconvolution of medical ultrasonic images is presented. The spatial resolution of the deconvolved images is much higher compared to the common images of the fundamental and second harmonic. The deconvolution also resultsin a more distinct speckle pattern. Unlike the most published deconvolution algorithms for ultrasonic images, the presented technique can be implemented using currently available hardware in real-time imaging, with rate up to 50 frames per second. Thismakes it attractive for application in the current ultrasound scanners. The algorithm is based on two-dimensional homomorphic deconvolution with simplified assumptions about the point spread function. Broadband radiofrequency image data are deconvolved instead of common fundamental-harmonic data. Thus, information of both the first and second harmonics is used. The method was validated on image data recorded from a tissue-mimicking phantom and on clinical image data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Ultrasonocs, Ferroelectrics, and Frequency Control
ISSN
0885-3010
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
1440-1448
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—