Level Set Method in EIT Image Reconstructions
Popis výsledku v původním jazyce
In present there are a lot of different numerical methods, ways and approaches to obtain the stable and effective image reconstruction process, which can be used for efficient applications in physical and biological sciences. Electrical Impedance Tomography (EIT) belongs to methods which are very beneficial, especially in a medical imaging. This method is non-invasive technique and can be used very effectively for good detection of conductivity tissue changes. Unfortunately the back image reconstructionbased on electrical impedance tomography is highly ill-posed inverse problem and it is necessary to find such techniques which offer stable, accurate and not too much time-consuming reconstruction process. This paper proposes new possibilities to improve the stability and the accuracy of today image reconstructions including the level set method.
Název v anglickém jazyce
Level Set Method in EIT Image Reconstructions
Popis výsledku anglicky
In present there are a lot of different numerical methods, ways and approaches to obtain the stable and effective image reconstruction process, which can be used for efficient applications in physical and biological sciences. Electrical Impedance Tomography (EIT) belongs to methods which are very beneficial, especially in a medical imaging. This method is non-invasive technique and can be used very effectively for good detection of conductivity tissue changes. Unfortunately the back image reconstructionbased on electrical impedance tomography is highly ill-posed inverse problem and it is necessary to find such techniques which offer stable, accurate and not too much time-consuming reconstruction process. This paper proposes new possibilities to improve the stability and the accuracy of today image reconstructions including the level set method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of PIERS 2010 in Cambridge
ISBN
978-1-934142-14-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Cambridge
Místo konání akce
Cambridge
Datum konání akce
5. 7. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—