Adaptive Filtering of Dynamic Contrast Enhanced Magnetic Resonance Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU91091" target="_blank" >RIV/00216305:26220/11:PU91091 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Adaptive Filtering of Dynamic Contrast Enhanced Magnetic Resonance Images
Popis výsledku v původním jazyce
Dynamic contrast enhanced T1-weighted magnetic resonance imaging (DCE-MRI) is a powerful tool for cancer diagnosis, monitoring of treatment effects and evaluation of anticancer drugs. To get information about perfusion and microcirculation in a tissue, four-dimensional (3 space coordinates and time) dataset must be processed, i.e. converted to represent concentration of contrast agent and fitted with proper model. Both these steps are sensitive to noise presented in the data. Noise in the DCE-MRI is notnegligible because high temporal and spatial samplings are required simultaneously. If signal to noise ratio (SNR) is too high, curve fitting of dilution curves with more sophisticated models is imprecise or not possible, hence noise suppression is important. Usual techniques for noise suppression as averaging in time or spatial domains remove high frequencies, which causes serious changes in the shapes of the dilution curves or blurring respectively. Median filtering is not useful beca
Název v anglickém jazyce
Adaptive Filtering of Dynamic Contrast Enhanced Magnetic Resonance Images
Popis výsledku anglicky
Dynamic contrast enhanced T1-weighted magnetic resonance imaging (DCE-MRI) is a powerful tool for cancer diagnosis, monitoring of treatment effects and evaluation of anticancer drugs. To get information about perfusion and microcirculation in a tissue, four-dimensional (3 space coordinates and time) dataset must be processed, i.e. converted to represent concentration of contrast agent and fitted with proper model. Both these steps are sensitive to noise presented in the data. Noise in the DCE-MRI is notnegligible because high temporal and spatial samplings are required simultaneously. If signal to noise ratio (SNR) is too high, curve fitting of dilution curves with more sophisticated models is imprecise or not possible, hence noise suppression is important. Usual techniques for noise suppression as averaging in time or spatial domains remove high frequencies, which causes serious changes in the shapes of the dilution curves or blurring respectively. Median filtering is not useful beca
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1690" target="_blank" >GA102/09/1690: Zvýšení potenciálu kontrastních zobrazovacích technik magnetické rezonance a ultrasonografie v lékařské diagnostice</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Abstract Book
ISBN
978-82-993786-6-6
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
88-88
Název nakladatele
University of Bergen
Místo vydání
Bergen
Místo konání akce
Bergen
Datum konání akce
17. 1. 2011
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—